04.00
02.99
5.1.4

Terminals

!
1)
E=input; A=output
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
Shutoff valves (axis-specific), external 26.5 V supply, enabling, BERO inputs
S
X431:
Axis 1
S
X432:
Axis 2
Table 5-4
Connector X431; 8-pin Phoenix Combicon connector
1)
Pin
X431
Type
1
M
E
Electronics ground
2
PV1
A
+24V shutoff valve axis 1
3
MV1
A
Ground for shutoff valve for axis 1
4
C1
Reserved, do not use!
5
P24
E
Input for +24 V external
6
M24
E
Input 0 V external
7
663
E
Module-specific enable signal
8
9
A
Internal +24 V enable voltage, term. 9
Table 5-5
Connector X432; 8-pin Phoenix Combicon connector
1)
Pin
X432
Type
1
M
E
Electronics ground
2
PV2
A
+24V shutoff valve axis 2
3
MV2
A
Ground for shutoff valve for axis 2
4
C2
Reserved, do not use!
5
B1
E
BERO input, axis 1
6
19
A
Internal enable voltage ground, term.19
7
B2
E
BERO input, axis 2
8
9
A
Internal +24 V enable voltage, term. 9
Max. terminal cross-section 2.5 mm
The +24 V outputs for shutoff valves for axes 1 and 2 are short-circuit-proof.
The energy absorbed when inductive loads are disconnected must be limited to
1.7 J by the user (see also Section 2.4.2). When the supply polarity is reversed,
the outputs are not protected against overload.
Warning
If the polarity of the 24 V supply is reversed, then the shutoff valves will open
immediately, even if the NC or closed-loop control is not in operation!
5 Hardware Drive Functions
5.1 Overview of interfaces
Function
Function
2
.
Typ. voltage/
limit values
max. 2.0 A
26.5 V "2 %
21 V...30 V
Typ. voltage/
limit values
max. 2.0 A
13 V...30 V
13 V...30 V
5-179

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digital

Table of Contents