Siemens SINUMERIK 840D Description Of Functions page 127

Hla module
Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

04.00
04.00
02.99
5482
DUAL_GAIN_COMP_SMOOTH_Z_R
Knee-point compensation rounding in zero range
Unit:
Default:
%
0.0
5483
NEG_DUAL_GAIN_COMP_Z_FLOW
Knee-point compensation neg. flow in zero range
Unit:
Default:
%
0.01
5484
NEG_DUAL_GAIN_COMP_Z_VOL T
Knee-point compensation neg. voltage in zero range
Unit:
Default:
%
0.0
5464
POS_DUAL_GAIN_COMP_FLOW
Knee-point compensation pos. flow
Unit:
Default:
%
10.0
5465
POS_DUAL_GAIN_COMP_VOL TAGE
Knee-point compensation pos. voltage
Unit:
Default:
%
10.0
5466
DUAL_GAIN_COMP_SMOOTH_RANGE
Rounding range for knee-point compensation
Unit:
Default:
%
2.5
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
Minimum:
Maximum:
0.0
10.0
Minimum:
Maximum:
0.01
95.0
Minimum:
Maximum:
0.0
95.0
To calculate the inverse characteristic, a knee-point is defined in the positive
zero range of the valve characteristic with MD 5480 and MD 5481 and in the
negative zero range with MD 5483 and MD 5484.
The positive and negative valve flows at the knee-point referred to rated flow
(MD 5107) are entered in 5480 and MD 5483 respectively.
The valve voltage at the knee-point referred to the rated valve voltage (MD
5109) is entered in MD 5481.
When MD 5481 is set to default zero, there is no breakpoint in the positive
zero range.
When MD 5484 is set to default zero, there is not breakpoint in the negative
zero range.
The rounding range is parameterized in MD 5482.
S
Valve characteristic with breakpoint in fine control range
Minimum:
Maximum:
0.2
95.0
Minimum:
Maximum:
0.2
95.0
Minimum:
Maximum:
0.0
10.0
4 Firmware Drive Functions
4.5 Output of manipulated variables
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
4-127