4 Firmware Drive Functions
4.13 Mounting functions
Valve spool
is not responding
5614
VALVE_ERROR_TIME
Valve spool monitoring timer
Unit:
Default:
ms
50
4.13.2

Variable signalling functions

5620
PROG_SIGNAL_FLAGS
Bits of variable signalling function
Bit 0= 0: Variable signalling function; not active
1: Variable signalling function; active
Bit1= 0: Segment of variable signalling function; address
space X
1: Segment of variable signalling function; address
space Y
Bit 2=0: Compar. var. sign. fct.; compare without sign
1: Compar. var. sign. fct.; compare with sign
Unit:
Default:
HEX
0
4-152
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
Minimum:
Maximum:
1
100
The valve spool position is returned on all Bosch valves. The message "Valve
spool is not responding" is output if the valve spool position exits the tolerance
field of 10 % of maximum stroke around the setpoint for longer than the time set
in MD 5614 when the power is enabled. This error message cannot be output if
no checkback signal is configured for the valve spool position (MD 5530).
Input bit field for controlling the variable signalling function.
Minimum:
Maximum:
0
7
Note
Bit 1 is effective only if signal number 0 is selected in MD 5621: PROG_SIG-
NAL_NR.
A random memory location from address space X or Y in the data RAM is moni-
tored for violation of a parameterizable threshold for the variable signalling func-
tion. A tolerance band can be set around this threshold; this is taken into ac-
count when the threshold is scanned for violation in either direction. Any
violation of the tolerance band is signalled to the PLC. This violation message
can be linked to a pickup and/or dropout delay. The signalling function operates
in a 4 ms cycle.
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
UNS.WORD
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
UNS.WORD
Immediately