3 Start-Up
3.11 Start-up functions
3.11
Start-up functions
Disabled softkeys
3-78
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
The following start-up functions are implemented for axes with HLA:
S
Measuring functions
– Measurement of valve control loop
– Measurement of velocity control loop
– Measurement of position control loop
S
function generator,
S
Circularity test
S
Servo trace
S
DAC configuration
Fig. 3-28
Menu display "Start-up functions"
The softkey "Self-opt. AM/MSD" in the "Start-up functions" menu is also disabled
for axes with HLA since this is a special function for AM/MSD.
Furthermore, softkey "AUT. Controller setting" in the "Startup functions" menu is
disabled for axes with HLA since the algorithms it uses are designed for auto-
matic controller setting for electrical digital drives.