DS1000/2000 Correspondence Course
DS1000 System Installation
Programming the Door Box
62
DS1000/2000 Workbook
Door Box Setup
You must assign the circuit type and chime pattern to each installed Door
Box.
1801: Extension Circuit Type
Enter 10 to assign the extension as a Door Box.
1801: Door Chime, enter the Door Chime type.
0 = Normal Ring Group ringing.
1 = Low pitch chime pattern.
2 = Mid range pitch chime pattern.
3 = High pitch chime pattern.
If you enter Door Chime type 0 (normal ring) above, you can set up
Call Coverage keys for the Ring Group. This allows extensions that
are not members of the Ring Group to answer Door Box calls.
Extensions with Call Coverage keys to the Door Box Ring Group
can also activate the relay (see Door Box Relay Control below).
Door Box Ringing
When a visitor at the door presses the Door Box call button, the Door Box
with alert (chime) all the extensions in the Ring Group to which the Door
Box belongs. For example, if the Door Box and extensions 301 and 302 are
in Ring Group 1, pressing the call button alerts 301 and 302.
1802: Ring Group Number
Assign the Door Box and the extensions that should alert to the same
Ring Group.
0511: Ring Group Master Extension Numbers and Names
Assign a Ring Group master number to the Ring Group assigned in the
previous step.
Door Box Relay Control
If the relay on the CPRU controls the strike for the door, the keyset that
answers the Door Box chimes can remotely open and close the strike.
0201: Door 1 Relay
Assign the Door 1 Relay for Door Box control, enter 1.
0201: Door 2 Relay
Assign the Door 2 Relay for Door Box control, enter 1.
1801: Relay Owner
Enter 1 to assign the CPRU PCB relay to the Door Box. Enter 0 to dis-
able the CPRU PCB relay for Door Box calls.
0401: Door Unlock Time
Enter the interval that the CPRU relay should remain closed after the
keyset user activates (closes) the relay. After this interval, the CPRU
automatically returns to its idle (open) state.