Rsla/Rela Scale Installation - Renishaw RESOLUTE FS with BiSS Series Installation Manual And Safety Manual

Safety encoder system
Table of Contents

Advertisement

RSLA/RELA scale installation

1
Thoroughly clean and
degrease the substrate
with a lint-free cloth.
Clean underside of scale using approved solvents
(see 'Storage and handling' on page 5)
4
Thoroughly mix and apply epoxy, then remove
remaining backing liner.
Area for
RGG-2 epoxy
(A-9531-0342)
5
Locate scale against dowels or ledge
and rotate down onto substrate.
Press down with firm
finger pressure.
RESOLUTE FS with BiSS
Safety encoder system installation guide and safety manual
®
2
Mark area for epoxy on
adhesive tape.
6
Support
dowels
Mounting ledge
3
Remove backing liner from one side
and stick to underside of scale.
7
or
8
Original instructions
Remove excess
epoxy
After 24 hours when epoxy
is cured, clean scale using
Renishaw scale wipes
(A-9523-4040) or a clean,
dry, lint-free cloth.
20