RSLA/RELA scale installation drawing
Dimensions and tolerances in mm
Alignment dowels, maximum spacing 350
Increasing count direction
NOTE: Head can be mounted in either orientation.
Encoder count direction is dependent only on scale orientation.
5
NOTE: Adhesive mounted scale should not be reused after installation.
*
RELA shown. RSLA installation is the same but the scale has no chamfers.
†
When scale is to be mounted vertically, position the dowels so that the datum edge is supported.
‡
Double-sided adhesive tape is included with all scale lengths.
RESOLUTE FS with BiSS
Safety encoder system installation guide and safety manual
®
* (Adhesive mounted RELA shown)
†
Measuring length, ML = (L-10)
Optical centreline
L
0.5
0.05/50
F = axis of motion
Adhesive datum clamp
12
RGG-2, 2-part epoxy, usually positioned
10
coincident with user selected scale datum
Original instructions
Datum edge
F
Double-sided adhesive tape
5
‡
19