RTLA30 scale and FASTRACK carrier installation
6
Slide RTLA30 scale into the FASTRACK ensuring
the scale is fed under the projections as shown.
Scale can be installed manually by either pulling
or pushing it through the FASTRACK carrier.
Alternatively use the optional
scale installation tool
as shown,
(A-9589-0420)
for easy installation.
8
Fix self-adhesive end covers
ensuring a gap of at least 1 mm.
Ensure a gap
> 1 mm
RESOLUTE FS with BiSS
®
Safety encoder system installation guide and safety manual
(Continued)
NOTE: For instructions on how to use the
scale installation tool, download 'User guide
– RTL scale installation tool
from the website at
www.renishaw.com/encoderinstallationguides
Projections
IMPORTANT: If manually installing
the scale using fingers, suitable
gloves should be worn to protect
against injury from sharp edges.
7
Create scale datum. Using dispensing tip P-TL50-0209
apply Loctite 435 between scale and FASTRACK so it
wicks underneath adjacent to user selected datum
location as shown.
NOTE: Mechanical datum clamp also available.
Please contact your local Renishaw representative
for more details.
'
(A-9589-0420)
NOTE: Only apply Loctite 435
in the locations shown.
Loctite 435 has been carefully selected
as it will wick under the scale to lock
it to the substrate.
9
Clean FASTRACK and
scale using a lint-free cloth.