Resa Ring Installation; Taper Mount Method - Renishaw RESOLUTE FS with BiSS Series Installation Manual And Safety Manual

Safety encoder system
Table of Contents

Advertisement

RESA ring installation

Mounting options
Taper mount
'A' section
'B' section
Not applicable
Enables simplest adjustment
Notes
Offers highest accuracy
Enables eccentricity to be compensated.
Offers excellent mechanical stability against
thermal cycling, shock and vibration.
Minimises cost of substrate preparation.
RESOLUTE FS with BiSS
Safety encoder system installation guide and safety manual
®
Interference fit
Alternative installation
Will not correct eccentricity of the
supporting shaft

Taper mount method

Step 1
Mounting shaft specifications
Recommended taper roundness
Diameter
Roundness value
(mm)
(mm TIR)
< 52
0.025
150 to 255
0.050
≥ 300
0.075
Recommended taper diameter (
)
DT
DO
DT
DO
(mm)
(mm)
(mm)
33.85
52
209
33.65
40.85
57
229
40.65
58.85
75
255
58.65
83.85
100
300
83.65
83.85
103
350
83.65
83.85
104
413
83.65
98.85
115
417
98.65
133.85
150
489
133.65
183.85
200
550
183.65
189.85
206
189.65
DO = Nominal external diameter
Recommended surface finish ≤ Ra 1.2
NOTE: It is recommended that the mounting surface is a turned, rather than ground finish.
Original instructions
DT
15° ±0.2°
7 min
1*
*
 Allow 2 mm for 417 mm, 489 mm and 550 mm rings only.
5 mm Max.
DT
(mm)
189.85
189.65
212.85
212.65
238.85
238.65
283.85
283.65
333.85
333.65
395.85
395.65
383.85
383.65
454.85
454.65
513.85
513.65
11

Advertisement

Table of Contents
loading