Renishaw RESOLUTE FS with BiSS Series Installation Manual And Safety Manual page 18

Safety encoder system
Table of Contents

Advertisement

Step 3
Adjust ring position until the
DTI (Dial Test Indicator) reading
at these points agrees to 10 µm.
'Slot' fiducial
Step 4
Now adjust the ring position until the
DTI (Dial Test Indicator) reading
at these points agrees to 10 µm.
'Dimple' fiducial
Step 5
Re-check the run-out at the two 'slot' fiducial points, to ensure the run-out at the two 'slot' points
is still better than 10 µm. Adjust if necessary.
Gradually tighten the 4 screws, a quarter-turn at a time, so as to avoid moving the position of
the ring. Finally, insert the remaining M5 screws and torque all the screws to 4 Nm.
Re-check the run-out at the two 'slot' fiducial points, then at the two 'dimple' fiducial points.
The run-out values at the 'slot' fiducial points do not have to match the run-out values at the
'dimple' fiducial points. If the ring has moved position outside the 10 µm limit, the screws must
be loosened and the ring adjusted.
RESOLUTE FS with BiSS
Safety encoder system installation guide and safety manual
®
'Slot' fiducial
'Dimple' fiducial
Original instructions
16