RGS40 scale installation drawing

>3
>5
30
13
P limit
<10
NOTE: The surface roughness of the scale mounting surface must be ≤3.2 Ra.
The parallelism of the scale surface to the axis of motion (readhead rideheight variation) must be within 0.05 mm.
RGH41 RGS40 installation guide
Overall length (ML + 70)
Scale length (ML + 40)
Reference mark actuator position range
0.5
F
0.2/100
F = axis of motion
6
(RGS40-S)
6.3
(RGS40-P)
Measuring length (ML)
Optional bolted reference mark actuator
(A-9531-0287)
>3
8
>5
Q limit
<10
Readhead optical centreline
Reference mark sensor position (inside readhead)
Dimensions and tolerances in mm
22
14
5
10
4