Rklc40-S Scale Installation Drawing - Renishaw QUANTiC RKLC40-S Installation Manual

Incremental linear encoder system
Hide thumbs Also See for QUANTiC RKLC40-S:
Table of Contents

Advertisement

RKLC40-S scale installation drawing

Dimensions and tolerances in mm
20
0.5
0.2 /100
F = axis of motion
13
30
P limit magnet
(dimensions as Q limit)
Nominal P limit trigger point
Ra 3.2
(Incremental and reference mark)
NOTES:
The reference mark selector and limit actuator locations are correct for the readhead orientation shown.
External magnetic fields greater than 6 mT, in the vicinity of the readhead, may cause false activation of the
limit and reference sensors.
1
20 mm when the Q limit is not used
2
Dimension from substrate.
3
Supplied with 2 M2 × 4 screws.
12
QUANTiC
RKLC40-S incremental linear encoder system
Overall length (L + 30)
Scale length (L)
Measuring length ML = (L − 40)
(ML = (L − 55) with dual limits)
Readhead optical detector position at extent of travel
9.2
F
A
P and Q limit switch
sensor position
Optical centreline
Reference mark selector magnet
(dimensions as Q limit)
6
Q limit magnet
IN-TRAC reference mark
0.05
F
F = axis of motion
Alternative bolted reference mark selector and limit magnets
Detail A
15 ±1
35
1
9.7
10
15
End clamp
Nominal Q limit trigger point
1.5
2
22
18
10
3
Ø2.2
1.85
3.7
18.5 ±1
3.7

Advertisement

Table of Contents
loading

Table of Contents