Field
Number_of_Images
E.2
GPIO_XTRA: 1104h
The GPIO_XTRA register controls when a strobe starts: relative to the start of integration (default) or relative to the
time of an asynchronous trigger. If the camera supports a rolling shutter with a global reset, the strobe can be set
to active from the start of exposure of the first line to the end of exposure on the last line (Any pixel) or from the
start of exposure on the last line to the end of exposure on the first line (All pixels).
Format:
Field
Strobe_Start
Shutter_Mode
Pixels_Exposed
E.3
FRAME_INFO: 12F8h
Field
Presence_Inq
ROI_Pos_Inq
GPIO_State_Inq
Strobe_Pat_Inq
Frame_Count_Inq
WB_CSR_Inq
Exp_CSR_Inq
Bright_CSR_Inq
Shutter_CSR_Inq
Gain_CSR_Inq
Time_Inq
2/10/2017
©2013-2017
FLIR Integrated Imaging
Solutions Inc. All rights reserved.
Bit
The number of images currently in buffer.
[20-31]
This field is read only.
Bit
Current Mode
[0]
0: Strobe start is relative to start of integration (default in free running)
1: Strobe start is relative to external trigger (default in trigger mode)
[1-12]
Reserved
Read only
[13]
0: Rolling shutter mode
1: Global reset mode
00: Line 1 exposed
01: Any pixel exposed (only available for global reset mode)
[14-15]
10: All pixels exposed (same as Line 1 for global reset mode)
11: Invalid
[16-31]
Reserved
Bit
Description
Presence of this feature
[0]
0: Not Available, 1: Available
[1-5]
Reserved
[6]
[7]
[8]
[9]
[10]
Presence of image-specific information display
0: Not Available, 1: Available
[11]
[12]
[13]
[14]
[15]