C
GenICam Features
The following features are included in the XML device description file on the camera to control, monitor, and query
the camera operation. Not all operations can be controlled using the XML file; those not included are controlled via
CSRs.
This file can be accessed via First URL bootstrap register 200h
C.1
Device Control
Name
DeviceVendorName
DeviceModelName
DeviceVersion
DeviceSerialNumber
DeviceUserID
DeviceGenCPVerMajor
DeviceGenCPVerMinor
DeviceFamilyName
Timestamp
TimestampLatch
TimestampIncrement
2/10/2017
©2013-2017
FLIR Integrated Imaging
Solutions Inc. All rights reserved.
Note: Except where noted, these features conform to the
GenICam Standard Features Naming Convention (SFNC) v1.5.
The full SFNC can be found on the
contains more details than provided below. Not all features are
available on all cameras.
Non-SFNC features are noted with a grey background.
Display Name
Vendor Name
Model Name
Device Version
Device Serial Number
Device User ID
Device GenCP Version
Major
Device GenCP Version
Minor
Family Name
Timestamp
Timestamp Latch
Timestamp Increment
Grasshopper
EMVA.org website
(GigE Vision Bootstrap
Description
Name of the
manufacturer
Model name of the
device
FPGA version
Camera Serial Number
User defined name
Major version of the
GenCP protocol
supported by the camera
Minor version of the
GenCP protocol
supported by the camera
Family name of the
device
Reports the current value
of the camera timestamp
counter
Latches the current
camera time into the
timestamp register
Indicates the timestamp
increment in ns/tick
®
3 PGE Technical Reference
C GenICam Features
and
Registers).
Value
Grasshopper3 PGE <model
number>
Grasshopper3 PGE
Write Only
101
Need help?
Do you have a question about the GRASSHOPPER 3 Series and is the answer not in the manual?