Manual Calibration - Graco SDP8 Series Installation And Operation Manual

Preset metered dispense valve
Table of Contents

Advertisement

8.
Press the center ENTER button on the
keypad again to select END and save the
new calibration factor.
9.
After selecting END the following screen
(F
. 18) displays.
IG
F
. 18
IG

Manual Calibration

NOTE: This Manual Calibration procedure is
used when the k-factor is known and a simple
adjustment of the displayed k-factor is
needed to set that number.
1.
Follow steps 1- 4 of the Calibration
instructions, beginning on page 13.
2.
Use the RIGHT ARROW button on the
keypad to highlight +/- and press the
center ENTER button on the keypad to
select the +/- option (F
F
. 19
IG
3A6673B
. 19).
IG
3.
The k-factor adjustment screen shown in
F
. 20 displays.
IG
F
. 20
IG
4.
Use the UP and DOWN ARROW to
increase or decrease the displayed
k-factor until the new k-factor displays on
the screen.
NOTE: Selecting the GO BACK Function
on this screen returns the display to the
previous screen (shown in F
Preset Mode
. 19).
IG
15