Preset Mode

Main Menu Screen

This screen provides access to the main
metered dispense valve functions:
DISPENSE, page 18
TOTAL, page 21
UTILITY MENU, page 21
F
. 11
IG

Calibration

NOTE:
This calibration procedure requires a
one quart or one liter clean, calibrated,
volumetric flask. When the meter is
configured to display fluid volume in
pints, quarts, or gallons, the calibration
procedure will require a one quart
calibrated, volumetric flask be used.
When the meter is configured in liters, a
one liter volumetric flask is required for
calibration.
The metered dispense valve must be
flushed and primed prior to calibration
(see Flushing, page 11).
The metered dispense valve should be
calibrated prior to using it for the first
time. Calibrating the metered dispense
valve assures that the dispenses are
accurate.
Calibration factors can vary due to fluid
viscosity and flow rate.
Calibrate the metered dispense valve for
specific fluids at nominal flow rates.
3A6673B
This calibration procedure requires a one
quart or one liter calibrated, volumetric flask.
If a one quart or one liter calibrated,
volumetric flask is not available, see Alternate
Calibration instructions, page 16.
To calibrate the metered dispense valve:
1.
Use the UP or DOWN ARROW button on
the keypad to highlight UTILITY MENU
(F
. 12) and then press the center
IG
ENTER button on the keypad to select
the UTILITY MENU option.
F
. 12
IG
2.
Use the UP or DOWN ARROW button on
the keypad to highlight SET-UP (F
and then press the center ENTER button
on the keypad to select the SET-UP
option.
F
. 13
IG
Preset Mode
. 13)
IG
13