D
DISPENSED FLUID COUNTER- As fluid is
dispensed, this number increases to reflect
the quantity of fluid that is being dispensed.
NOTE: If RESET was not selected after the
previous dispense was completed, the
amount of fluid dispensed in the previous
dispense will be shown in this field. If
RESET was selected, the field will show
0.000.
E
UNIT OF MEASURE - Pints, Quarts, Gal-
lons or Liters. For instructions on setting the
Unit of Measure see UTILITY
MENU/SET-UP/UNIT OF MEASURE, page
23.
F
PROGRESS BAR - Graphic representation
of the progression of the dispense shown by
gradually filling-in the empty space in the
bar. A textual representation of the progress
is also shown in a percentage format.
G
PRESET AMOUNT - The volume of fluid
that the meter is currently set up to dispense
in PRESET Mode. See UTILITY
MENU/SET-UP/PRESET, page 25.
H
ADJUSTABLE PRESET - Shows the vol-
ume of fluid that the meter is currently set up
to dispense in PRESET. Press the UP or
DOWN arrow on the keypad to increase or
decrease this quantity.
J
DISPENSED - The amount of fluid previ-
ously dispensed.
K
INCREASE/DECREASE ARROW - The
up/down arrow on the screen indicates the
user can increase or decrease the PRESET
quantity before starting the dispense. Use
the UP or DOWN ARROW button on the key
pad to increase or decrease the PRESET
amount.
L
PRESET SELECTION - The left and right
arrow on the screen indicate the user can
select a different PRESET option (1-5).
Press the LEFT or RIGHT ARROW button
on the key pad to scroll through the PRESET
options 1 - 5 (set up in UTILITY
MENU/SET-UP/PRESET, page 25).
3A6673B

Preset Dispense

1.
Wake up the metered dispense valve by
pressing any button on the key pad (F
1, page 7).
2.
If ACTIVATE (A) is not highlighted, use
the LEFT or RIGHT ARROW button on
the keypad to highlight ACTIVATE (F
31); then press the center, ENTER
button on the keypad to select it.
The following screen (F
after ACTIVATE is selected.
D
F
F
. 32
IG
3.
Squeeze the trigger to dispense fluid. A
numeric volume of dispensed fluid
displays in field (D) and increases while
the fluid is dispensed.
The progress bar (F) fills-in and a
numeric percentage increases as the
amount of fluid dispensed nears the
Preset amount.
4.
When the PRESET amount of fluid has
been dispensed the trigger deactivates,
stopping the fluid flow.
Preset Mode
. 32) displays
IG
.
IG
.
IG
19