Dispense - Graco SDP8 Series Installation And Operation Manual

Preset metered dispense valve
Table of Contents

Advertisement

Preset Mode
11. Calculate the new k-factor using the
following equation:
Example:
Kcurrent = 169
Volume displayed on metered dispense valve
= 0.970 quart
Volume dispensed = 1 quart
Round to the nearest whole number: 163.9 =
164.
NOTE: The unit of measurement for both
volumes must be the same in the above
equation.
12. Use the UP or DOWN ARROWS to
adjust the k-factor to the k-factor (Knew)
calculated in Step 11.
See Table 1, page 18 for recommended fluid
calibration factors.
NOTE: The calibration number may vary
slightly due to temperature or rate of flow.
Table 1
Fluid
Oil (10W30)
Gear Lube
ATF
Antifreeze
13. Press the center ENTER button on the
keypad to complete the calibration
operation and save the new calibration
factor.
18

DISPENSE

F
A
B
Calibration
Factor
C
173
173
173
150
DISPENSE SCREEN
A
D
E
F
PRESET ADJUSTMENT SCREEN
J
L
H
. 31
IG
BANNER - Unique identification name. See
Utility Menu/Set-Up/BANNER, page 23 for
instructions for creating the banner.
BATTERY INDICATOR - When the batter-
ies are fully charged, the battery is com-
pletely filled in. As the battery discharges,
the amount of battery that is filled-in
declines.
FUNCTION COMMAND - Function com-
mand options appear at the bottom of the
display when applicable to the task being
performed. Options when in the Dispense
mode include:
ACTIVATE - Activates the trigger to begin a
dispense.
PRESET - Preset dispense adjustment
screen displays.
RESET - Resets the dispense settings.
ENTER - Saves changes or updates.
NOTE: Additional function commands will
appear throughout the following instruc-
tions. when applicable
B
G
C
K
H
3A6673B