Page 1
Operation ® ProMix 312776K Plural Component Proportioner Manual system for proportional mixing of plural component coatings. For professional use only. Approved for use in explosive atmospheres (except the EasyKey). See page 4 for model information, including maximum working Important Safety Instructions pressure.
Fluid Station and EasyKey Manual Description See F . 1 on page 5 for label locations. 312775 ProMix 2KS Manual System Installation EasyKey and Fluid Station Label 312777 ProMix 2KS Manual System Repair-Parts 312781 Fluid Mix Manifold...
System Configuration and Part Numbers System Configuration and Part Numbers Configurator Key The configured part number for your equipment is printed on the equipment identification labels. See F for location of the identification labels. The part number includes one digit from each of the following six categories, depending on the configuration of your system.
26A099 7 Color/1 Catalyst Change Kit 26A100 12 Color/1 Catalyst Change Kit NOTE: This is not a complete list of available accesso- ries and kits. Refer to the Graco website for more infor- mation about accessories available for use with this product.
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
Page 8
Warnings WARNING SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Tighten all fluid connections before operating the equipment.
Important Two-Component Material Information Important Two-Component Material Information Material Self-ignition Isocyanates (ISO) are catalysts used in two component materials. Isocyanate Conditions Some materials may become self-igniting if applied too thick. Read material manufacturer’s warnings and Safety Data Sheet (SDS). Spraying or dispensing materials that contain Keep Components A and B isocyanates creates potentially harmful mists, vapors, and atomized particulates.
Important Two-Component Material Information Moisture Sensitivity of NOTE: The amount of film formation and rate of crystal- lization varies depending on the blend of ISO, the Isocyanates humidity, and the temperature. Exposure to moisture (such as humidity) will cause ISO Changing Materials to partially cure;...
Important Acid Catalyst Information Important Acid Catalyst Information The 2KS Plural Component Proportioner is designed for acid catalysts (“acid”) currently used in two-component, wood-finishing materials. Current acids in use (with pH levels as low as 1) are more corrosive than earlier acids. More corrosion-resistant wetted materials of construction are required, and must be used without substitution, to withstand the increased corrosive properties of these acids.
Glossary of Terms Glossary of Terms Advanced Web Interface (AWI) - This allows remote Coriolis Meter - a non-intrusive flow meter often used in ProMix backup and restore, configuration, logging, and low flow applications or with light viscosity, shear sensi- software update options.
Page 13
Glossary of Terms First Purge Source- source of the media used in the K-factor - a value that refers to the amount of material first purge cycle. User settable to air purge valve, sol- that passes through a meter. The assigned value refers vent purge valve, or 3rd purge valve to an amount of material per pulse.
Page 14
Glossary of Terms Overdose (A, B, C) Alarm - when either the resin (A), Third Purge Valve - refers to the use of three purge or catalyst (B), or reducer (C) component dispenses too valves used to flush some waterborne materials. The much material and the system cannot compensate for valves are used to flush with water, air and solvent.
Overview Usage The Graco ProMix 2KS is an electronic two-component paint proportioner. It can blend most two-component solvent and waterborne epoxy, polyurethane, and acid-catalyzed paints. It is not for use with “quick-setting” paints (those with a potlife of less than 15 minutes).
Page 16
Overview Table 1: Component Descriptions Component Description Three optional flow meters are available from Graco: Flow Meters (MA, MB, MS) • G3000 is a general purpose gear meter typically used in flow ranges of 75-3800 cc/min. (0.02–1.0 gal/min.), pressures up to 4000 psi (28 MPa, 276 bar), and viscosi- ties of 20–3000 centipoise.
Page 17
Overview BCV - acid models TI29655a . 2. Manual System, shown with G3000 Meters, Color/Catalyst Change, One Gun Flush Box, and Accessory Solvent Flow Meter 312776K...
Page 18
Overview TI12556b . 3. Wall Mount Fluid Station Key: Component A Meter DVA Component A Dose Valve RVA Component A Sampling Valve SVA Component A Shutoff Valve Component B Meter DVB Component B Dose Valve RVB Component B Sampling Valve SVB Component B Shutoff Valve Solvent Meter (accessory) SPV Solvent Purge Valve...
Booth Control Booth Control Used by the operator for daily painting functions includ- Table 2: Booth Control Key and Indicator Functions ing: changing recipes, signalling job complete, read- (see F . 4) ing/clearing alarms, and placing the system in Standby, Key/Indicator Definition and Function Mix, or Purge mode.
EasyKey Display and Keypad EasyKey Display and Keypad Keypad LCD Display TI11630A Navigation Keys Alarm Reset Key . 5. EasyKey Display and Keypad Display Table 3: EasyKey Keypad Functions (see F . 5) Shows graphical and text information related to setup Function and spray operations.
Connector Ports TI12638a TI12657a . 6. EasyKey Connections and AC Power Switch AC Power Switch Graco Web Interface Port Turns system AC power on or off. Used to communicate from a PC to: Upgrade software I/S Power View software version ...
. 9 for a map of the Run screens. Detailed screen descriptions follow. Splash Screen At power up, the Graco logo and software revision will display for approximately 5 seconds, followed by the Status Screen (see page 24). . 7. Splash Screen The Splash screen will also momentarily display “Estab-...
Page 23
Run Mode Screens Press the Setup key to enter Setup mode. TI12783a . 9. Run Screens Map 312776K...
Run Mode Screens Status Screen Potlife Timer: shows remaining potlife time in min- utes. Two times are shown if there are two guns. • Use the Up or Down keys to scroll through the Run screens. Status Bar: shows current alarm or operation mode (standby, mix, purge, recipe change, or the current alarm).
Run Mode Screens Totals Screen Reset Total Screen . 11. Totals Screen . 12. Reset Total Screen This screen shows the job totals, fill totals, grand totals, If job is reset, job number will increment by one for and job number. Use the tabs to reset job totals (Job default.
Run Mode Screens Alarms Screens occur after 25% of the remaining volume is mixed. Refill tank volume to clear the alarm. . 14. Alarms Screen . 16. Tank Level Low Screen (Tank A Shown) Two screens show the last 10 alarms. Use the Up Down keys to scroll between the two screens.
Setup Mode Setup Mode NOTE: See F . 17 for a map of the Setup screens. Press the Setup key to enter Setup mode. Detailed screen descriptions follow. Press the Setup key to enter Setup mode. This screen appears only if a password is activated.
Home Screen. Entering the wrong password returns the display to the Status Screen. NOTE: If you forget the password, you can reset the password (to 0), using the ProMix 2KS Web Interface (see manual 313386). . 20. Set Up Home Screen This screen displays when you enter Setup mode.
Page 29
Setup Mode Table 4: Component Software Versions Display (may vary from Component examples shown) Description EK (EasyKey) 3.01.001 EasyKey software version. FP (Fluid Plate) 3.01.001 Fluid Plate software version. BC (Booth Control) Booth Control not installed, not detected, or not operational. 1.XX Booth Control software version 1.00 or 1.01.
Setup Mode System Configuration Screens NOTE: See F . 21 for a map of the System Configura- NOTE: Each screen displays the current screen number tion Screens. Detailed screen descriptions follow. and the total number of screens in the group. TI12785a .
Page 31
Setup Mode Configure Screen 1 Screen Timeout Select the desired screen timeout in minutes (0-99). 5 is the default. Configure Screen 2 . 22. Configure Screen 1 Language Defines the language of the screen text. Select English . 23. Configure Screen 2 (default), Spanish, French, German, Italian, Dutch, Jap- anese (Kanji), Korean, Chinese (Simplified), and Cus- tom.
Page 32
Setup Mode Configure Screen 3 Configure Screen 4 . 24. Configure Screen 3 . 25. Configure Screen 4 1K/2K/3K Dose Time Alarm Set this value to indicate the system performance level Enter the dose time (1 to 99 seconds). This is the designation.
Page 33
Special Outputs Use of Special Outputs on Manual systems requires installation of a Discrete I/O Integration Board. Order Graco Part No. 15V825 Discrete I/O Integration Board Kit. See manual 406800. NOTE: At system power up, the Special Outputs may activate for up to 1/4 second.
Setup Mode Option Screens NOTE: See F . 21 on page 30 for a map of the Option Minimum Material Fill Volume Screens. Detailed screen descriptions follow. Enter 0-9999 cc. NOTE: Each screen displays the current screen number Verification Screen and the total number of screens in the group.
Page 35
Setup Mode Option Screen 2 B Purge After Chop NOTE: This is used to isolate the Chop cycle from the Final Purge cycle with solvent to prevent reaction issues with some types of materials. Optional 2-second burst (2 s B) operation of the B Purge valve on the integrator after the Chop cycle.
Setup Mode Advanced Setup Screens NOTE: See F . 32 for a map of the Advanced Setup Screens. Detailed screen descriptions follow. Advanced Setup screens 2, 3, 4, and 5 appear depending on selections made in Option screens 1 and 2. TI12786a .
Page 37
Setup Mode NOTE: Each screen displays the current screen number Color/Catalyst Fill and the total number of screens in the group. The total This field only appears if the system includes a color number of screens in a group and the fields displayed change module and Flush and Fill Input is set to on each screen may vary depending on selections “Global”...
Page 38
Setup Mode Advanced Setup Screen 3 Advanced Setup Screen 4 . 35. Advanced Setup Screen 3 . 36. Advanced Setup Screen 4 This screen appears only if Flush and Fill Input is set to This screen appears only if K-factor Input is set to “Global”...
Page 39
Setup Mode Advanced Setup Screen 5 . 37. Advanced Setup Screen 5 This screen appears only if Flush and Fill Input is set to “Global” in Option Screen 1, page 34 and Special Out- puts is set to 1, 2, 3, or 4 in Configure Screen 5, page 33.
Setup Mode Recipe Setup Screens NOTE: See F . 38 for a map of the Recipe screens. Detailed screen descriptions follow. Recipe 0 Screens Recipe screens 3, 4, 5, 6, and 7 appear depending on selections made in Option screens 1 and 2 TI12787a .
Page 41
Setup Mode NOTE: Each screen displays the current screen number Recipe Setup Screen 2 and the total number of screens in the group. The total number of screens in a group and the fields displayed on each screen may vary depending on selections made in the System Configuration Screens and Option Screens.
Page 42
Setup Mode Recipe Setup Screen 3 Recipe Setup Screen 4 . 42. Recipe Setup Screen 4 . 41. Recipe Setup Screen 3 This screen appears only if Flush and Fill Input is set to This screen appears only if Flush and Fill Input is set to “Recipe”...
Page 43
Setup Mode Recipe Setup Screen 5 Recipe Setup Screen 6 . 43. Recipe Setup Screen 5 . 44. Recipe Setup Screen 6 This screen appears only if K-factor Input is set to “Rec- This screen appears only if Flow Rate Monitor is set to ipe”...
Page 44
Setup Mode Recipe Setup Screen 7 . 45. Recipe Screen 7 This screen appears only if Flush and Fill Input is set to “Recipe” in Option Screen 1, page 34 and Special Out- puts is set to 1, 2, 3, 4, or “3 + GFB on #4” in Configure Screen 5, page 33.
Setup Mode Recipe 0 Screens Air Chop Time Enter the air chop time (0.0 to 99.9 seconds). NOTE: See F . 38 on page 40 for a map of the Recipe 0 screens. Detailed screen descriptions follow. Solvent Chop Time/3rd Flush Valve Chop Time Enter the solvent or 3rd flush valve chop time (0.0 to Recipe 0 is typically used: 99.9 seconds).
Page 46
Setup Mode Recipe 0 Screen 3 Recipe 0 Screen 4 . 48. Recipe 0 Screen 3 . 49. Recipe 0 Screen 4 This screen only appears if Solvent Monitor is set to This screen appears only if Flush and Fill Input is set to “Meter”...
Setup Mode Calibration Screen . 50. Calibration Screen Use this screen to calibrate a meter. Set to “A Meter,” “B Meter,” or “Solvent Meter” (available if Solvent Monitor in Configure Screen 5, page 33, is set to “Meter”). • Start - start calibration •...
2. The operator presses the Mix key to begin Standby operation. Stops the system. 3. The ProMix 2KS controller sends signals to activate the solenoid valves. The solenoid valves activate Dose Valves A and B. Fluid flow begins when the Purge gun is triggered.
Page 49
NOTE: To control output from the static mixer to the gun, install an optional fluid pressure regulator. 8. When the gun is triggered again, the ProMix 2KS continues the process where it left off. 6. Components A and B are alternately fed into the NOTE: Operation can be stopped at any time by integrator as long as the gun is triggered.
System Operation General Operating Cycle, Dynamic Dosing Overview Dynamic Dosing System Parameters Dynamic Dosing provides on-demand proportioning, The following parameters affect dynamic dosing perfor- eliminating the need for an integrator and therefore min- mance: imizing undesired material contact. This feature is espe- cially useful with shear-sensitive and waterborne •...
Page 51
Install the 15U955 Injection Kit in the fluid manifold as To enable DD setup mode, select On in the DD explained in the ProMix 2KS Installation manual. Use setup mode drop down menu. This disables Off the charts provided in that manual to select an appropri-...
Page 52
System Operation Balancing A/B Pressure If component B pressure is too high, it will push the com- B Pressure ponent A stream aside during B injection. The valve will Too Low not open long enough, causing a High Ratio alarm. B Pressure If component B pressure is too low, it will not be injected in sufficient volume.
System Operation Table 6: Dynamic Dosing Troubleshooting Guide (for complete system troubleshooting, see Table 11 beginning on page 83) Warning/Alarm Message Solution B Pressure Too Low (see F . 56) • Increase B pressure. • Clean restrictor or use a larger size. •...
Dose Time Alarm (E-7 or E-8) occurs after 40 seconds and the system shuts down. • Since the ProMix 2KS does not know it is spraying because there is no gun trigger/air flow switch input, it will go into System Idle (E-15) every 2 minutes when in Mix mode.
System Operation Start Up Graco logo, software revision, and “Establishing 1. Go through the Pre-Operation Checklist in Table 8. Communication” will display, followed by Status Table 8: Pre-Operation Checklist screen. See page 22. At power up the system defaults to Recipe 61, ...
Page 56
System Operation 6. Adjust component A and B fluid supplies Watch the fluid flow rate displayed on the Status as needed for your application. Use low- screen while the gun is fully open. Verify that the est pressure possible. flow rate of components A and B are within 10% of each other.
Pressure Relief Procedure NOTE: The following procedures relieve all fluid and air Overnight Shutdown pressure in the ProMix 2KS system. Use the procedure 1. Leave the power on. appropriate for your system configuration. 2. Run Recipe 0 to purge solvent through meters and gun.
Page 58
System Operation Systems with Color Change and without Systems with Color/Catalyst Change and Dump Valves Dump Valves NOTE: This procedure relieves pressure through the NOTE: This procedure relieves pressure through the sampling valve. dump valves. 1. Complete all steps under Single Color Systems, 1.
Page 59
System Operation Power Fiber Optic Dose A Valve Dose B Dump Valve A Dump Valve B Optional Solenoid GFB 1 Locations GFB 2 3rd Purge Valve Dose Valve A Solenoid Solenoid Dose Valve B Purge Valve A Purge Valve B Solenoid Solenoid Solenoid...
Page 60
System Operation Solenoid Solenoid Identification Identification Label Label TI12826a Solvent Solenoid Overrides . 66: Color Change Solenoids Key: Component A Meter DVA Component A Dose Valve RVA Component A Sampling Valve SVA Component A Shutoff Valve Component B Meter DVB Component B Dose Valve RVB Component B Sampling Valve...
System Operation Purging If using an electrostatic gun shut off the electrostatics before flushing the gun. Read Warnings, page 7. Follow the Grounding instructions in your system Installation manual. 2. Set the solvent supply pressure regulator at a pres- To avoid splashing fluid in the eyes, wear eye protec- sure high enough to completely purge the system in tion.
Page 62
System Operation Purging Using Recipe 0 Purging Fluid Supply System Recipe 0 is typically used: Follow this procedure before: • in multiple color systems to purge out material lines • the first time material is loaded into equipment* without loading a new color •...
Page 63
System Operation 3. Adjust the solvent fluid supply pressure. Use the lowest possible pressure to avoid splashing. 4. Remove the Fluid Station cover to access the sole- noid valves. See F . 65. 5. Purge as follows: • Single color/single catalyst systems: Purge component A side.
Page 64
System Operation Purging Sampling Valves and Tubes 8. Close sampling valves. Follow this procedure after meter calibration. NOTE: Select Abort on Calibration screen to cancel current calibration and close dose or purge valves. 1. Press the Standby key on the Booth Control. 9.
(0-99%) of the 50% of the potlife volume. Solvent Push requires an accessory solvent meter (MS). Order Graco Part No. 16D329 S3000 Solvent Meter Kit. NOTE: To manually interrupt Solvent Push, press the See manual 308778.
Mix Fill Push requires an accessory Gun Flush Box for 3. After waiting for the 2-minute Auto Dump time the each gun that will use this feature. Order Graco Part No. system will run the Mix Fill Push. 15V826 Fun Flush Box Kit. See manual 312784.
Meter Calibration Meter Calibration 4. Place the beakers (minimum size - 250 cc) in hold- ers. Put the sampling tubes into the beakers. NOTE: If tubes need replacing, use 5/32 in. or 4 mm OD tubing. To avoid splashing fluid in the eyes, wear eye protec- tion.
Page 68
12. After the volume for A, B, or Solvent is entered, the 8. Dispense component A, B, or Solvent into beaker. ProMix 2KS controller calculates the new flow meter K-factor and shows it on the Calibration Screen. NOTE: K-factor values on the screen are viewable only.
Color Change Color Change Color Change Procedures Color Change Sequences . 71 through F . 80 illustrate various color change Multiple Color Systems sequences. See Table 9 to determine which figure to reference, based on the recipe change and system con- 1.
Page 70
Color Change Color Purge/Dump First Purge • This sequence flushes out the color with solvent, Select the First Purge Source (air, solvent, or 3rd valve) from the color valve to the Dump A valve. and First Purge Time. For most applications, air is selected.
Page 71
Color Change Table 9: Color Change Chart Reference Starting Ending Change Recipe Recipe Type Dump A Exiting Fill Refer to Fig. Change . 71 Change . 72 Fill . 73 Fill . 74 Fill . 75 Fill . 76 Purge .
Page 72
<- Length -> Special Output #3 <- Length -> <- Length -> Special Output #4 <- Length -> <- Length -> 3 + GFB on #4 2KS X to Y K15 . 71: ProMix 2KS Recipe Change Chart #1 X to Y...
Page 73
<- Length -> Special Output #3 <- Length -> <- Length -> Special Output #4 <- Length -> <- Length -> 3 + GFB on #4 2KS X to Y K13 . 72: ProMix 2KS Recipe Change Chart #2 X to Y...
Page 74
<- Length -> Special Output #3 <- Length -> <- Length -> Special Output #4 <- Length -> <- Length -> 3 + GFB on #4 2KS 0 to Y K15 . 73: ProMix 2KS Recipe Fill Chart #3 0 to Y...
Page 75
<- Length -> Special Output #3 <- Length -> <- Length -> Special Output #4 <- Length -> <- Length -> 3 + GFB on #4 2KS 0 to Y K14 . 74: ProMix 2KS Recipe Fill Chart #4 0 to Y...
Page 76
<- Length -> Special Output #3 <- Length -> <- Length -> Special Output #4 <- Length -> <- Length -> 3 + GFB on #4 2KS 0 to Y K13 . 75: ProMix 2KS Recipe Fill Chart #5 0 to Y...
Page 77
<- Length -> Special Output #3 <- Length -> <- Length -> Special Output #4 <- Length -> <- Length -> 3 + GFB on #4 2KS 0 to X K12 . 76: ProMix 2KS Recipe Fill Chart #6 0 to Y...
Page 78
<- Length -> Special Output #3 <- Length -> Special Output #4 <- Length -> 3 + GFB on #4 This activates for Autodump operations only 2KS X to 0 K15 . 77: ProMix 2KS Recipe Purge Chart #7 X to 0...
Page 79
<- Length -> Special Output #3 <- Length -> Special Output #4 <- Length -> 3 + GFB on #4 This activates for Autodump operations only 2KS X to 0 K13 . 78: ProMix 2KS Recipe Purge Chart #8 X to 0...
Page 80
<- Length -> Special Output #2 <- Length -> Special Output #3 <- Length -> Special Output #4 <- Length -> 3 + GFB on #4 2KS 0 to 0 K3 . 79: ProMix 2KS Recipe Purge Chart #9 0 to 0...
Page 81
<- Length -> Special Output #2 <- Length -> Special Output #3 <- Length -> Special Output #4 <- Length -> 3 + GFB on #4 2KS 0 to 0 K1 . 80: ProMix 2KS Recipe Purge Chart #10 0 to 0...
Tank B Low Alarm Page 92 the date/time stamped log, which can be viewed on a E-24 Tank S Low Alarm Page 92 PC, using the ProMix 2KS Web Interface (see manual 313386). E-25 Auto Dump Complete Alarm Page 93 E-26...
Alarm Troubleshooting Alarm Troubleshooting Table 11. Alarm Troubleshooting E-1: COMM ERROR Cause Solution No power to the EasyKey. Connect power to EasyKey. No power to Fluid Station. The intrinsically safe power Verify that the cable is correctly connected. See Installa- cable between the EasyKey and Fluid Station is not con- tion manual.
Page 84
Slow actuation of the component A or B valves. This can Manually operate the Dispense A and B solenoid valves be caused by: as instructed in the ProMix 2KS Repair-Parts manual to check operation. • Air pressure to the valve actuators is too low.
Page 85
Slow actuation of the component A or B valves. This can Manually operate the Dispense A and B solenoid valves be caused by: as instructed in the ProMix 2KS Repair-Parts manual to check operation. • Air pressure to the valve actuators is too low.
Page 86
(such as fans and conveyors). 3. Check if the ProMix 2KS is reading any fluid flow. 4. If the ProMix 2KS shows there is fluid flow and there are no leaks from the gun or any other seals or fit- tings, the flow meters are probably being affected by pressure pulsations.
Page 87
Alarm Troubleshooting Table 11. Alarm Troubleshooting E-7: DOSE TIME A ALARM and E-8: DOSE TIME B ALARM E-7: gun trigger input is active (AFS or Integration) and fewer than 31 A meter pulses were detected during the dose time selected. E-8: gun trigger input is active (AFS or Integration) and fewer than 31 B meter pulses were detected during the dose time selected.
Page 88
E-11: PURGE VOLUME ALARM Cause Solution ProMix 2KS solvent flow switch is not activated while Verify that the gun is not shut off and that the solvent purging. flow switch is activated while purge is taking place. Minimum flush volume is not achieved.
Page 89
Alarm Troubleshooting Table 11. Alarm Troubleshooting E-12: CAN COMM ERROR ALARM Cause Solution Communication between the Color Change Module and • Verify that all cables are connected securely and that the Fluid Station is interrupted. the Color Change and Booth Control power LEDs turn on.
Page 90
Alarm Troubleshooting Table 11. Alarm Troubleshooting E-13: HIGH FLOW ALARM or E-14: LOW FLOW ALARM (may also be set as Warnings) Cause Solution Fluid system is producing too much or too little flow. Troubleshoot fluid system for restrictions, leaks, exhausted fluid supply, incorrect settings, etc. Increase or decrease flow rate, as required.
Page 91
Alarm Troubleshooting Table 11. Alarm Troubleshooting E-19: I/O ALARM Cause Solution The Mix and Purge digital inputs are on at the same time. Ensure that only one input is on at a time. At least 1 sec delay is required when switching from Mix to Purge or vice versa.
Page 92
Alarm Troubleshooting Table 11. Alarm Troubleshooting E-20: PURGE INITIATE ALARM Cause Solution System detects atomizing air to the gun when purge is Shut off gun air. selected. For systems with a gun flush box, gun is not in the box Place gun in gun flush box.
Page 93
Alarm Troubleshooting Table 11. Alarm Troubleshooting E-25: AUTO DUMP COMPLETE ALARM Cause Solution A potlife alarm is active for more than 2 minutes, the gun Be sure to spray all mixed material before potlife expires. flush box is enabled and gun is in the gun flush box, and an auto dump flush sequence is complete.
Schematic Diagrams Schematic Diagrams System Pneumatic Schematic COLOR COLOR CHANGE VALVE CONTROL STACKS AIR EXHAUST MUFFLER MANIFOLD COLOR 1 COLOR 2 12 VDC COLOR 3 COLOR 4 DOSE A VALVE 4-WAY SOLENOID COLOR 5 COLOR 6 COLOR 7 COLOR 8 12 VDC COLOR SOLVENT DOSE B...
Schematic Diagrams System Electrical Schematic NOTE: The electrical schematic illustrates all possible wiring expansions in a ProMix 2KS system. Some compo- nents shown are not included with all systems. Non-Hazardous Area NON-HAZARDOUS AREA LINE OPERATOR INTERFACE FILTER DC OK 85-250 VAC...
Page 96
Schematic Diagrams System Electrical Schematic NOTE: The electrical schematic illustrates all possible wiring expansions in a ProMix 2KS system. Some compo- nents shown are not included with all systems. Hazardous Area HAZARDOUS AREA FLUID PANEL CONTROL BOX 3X CABLE FLUID...
Air filter inlet size ....... 3/8 npt(f) Air filtration for air logic and purge air (Graco-supplied) . . 5 micron (minimum) filtration required; clean and dry air Air filtration for atomizing air (user-supplied) .
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.