Alternate Calibration - Graco SDP8 Series Installation And Operation Manual

Preset metered dispense valve
Table of Contents

Advertisement

Preset Mode
5.
Be sure ENTER is highlighted in the
lower left corner of the display as shown
in F
. 21. Press the center ENTER
IG
button on the keypad to save the new
calibration factor.
F
. 21
IG
6.
After selecting ENTER the following
screen (F
. 22) displays.
IG
F
. 22
IG

Alternate Calibration

NOTE: This alternate calibration procedure is
used when a one quart or one liter calibrated,
volumetric flask is not available.
1.
Dispense a known volume of fluid into
any sized clean, calibrated, volumetric
flask. Note this volume as the VOLUME
DISPENSED (see Calculating k-factor,
Step 11, page 18).
16
2.
Record the volume displayed on the
metered dispense valve. Note this
volume as the VOLUME DISPLAYED
ON THE METERED DISPENSE VALVE
(see Calculating the k-factor, Step 11,
page 18).
3.
Use the UP or DOWN ARROW button on
the keypad to highlight UTILITY MENU
(F
. 23) and then press the center
IG
ENTER button on the keypad to select
the UTILITY MENU option.
F
. 23
IG
4.
Use the UP or DOWN ARROW button on
the keypad to highlight SET-UP (F
and then press the center ENTER button
on the keypad to select the SET-UP
option.
F
. 24
IG
. 24)