Page 1
Integrated air controls for use with NXT Model 2200, 3400, and 6500 Air Motors. 100 psi (0.69 MPa, 6.9 bar) Maximum Regulated Working Pressure NXT011, Series E With locking air regulator and 110 psi (0.76 MPa, 7.6 bar) relief valve NXT021, Series E With non-locking air regulator and 110 psi (0.76 MPa, 7.6 bar) relief valve...
Installation Installation 3. Turn air regulator knob (C) fully counterclockwise. Air Control Modules NXT011 and NXT031 (locking air regulator) and NXT021 (non-locking air regula- tor) are available. 1. Install supplied o-ring (43) into counterbore on upper side of air control module (D). Fasten module to air motor (M) with two supplied screws (44).
Component Identification Key for F Air Inlet, 3/4 npt(f) Bleed-type Master Air Valve Air Control Modules NXT011 and NXT031 (locking Air Regulator Adjustment Knob (locking or non-locking) air regulator) and NXT021 (non-locking air regula- Air Pressure Gauge tor) include air line components in an integrated...
Page 5
Operation Startup Locking Regulator (NXT011 and NXT031 only) 1. Turn air regulator knob (C) fully counterclockwise. 1. To lock pressure setpoint, push knob (C) in. TI8322c TI8236c 2. Open bleed-type master air valve (B). 2. Pull knob out to unlock, then adjust regulator to desired pressure setpoint.
Troubleshooting Troubleshooting Problem Cause Solution Air leaking from regulator housing, or Loose or worn diaphragm (17d). Tighten housing or repair regulator gauge shows unstable regulated using repair kit NXT095. See page 8. pressure. Worn seat (17e) or poppet (17f). Repair regulator using repair kit NXT095.
Repair Repair Pressure Relief Procedure Replace Filter Element 1. Relieve pressure, page 7. Follow Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing 2. Remove filter bowl (E) with wrench. Remove filter equipment. element (G). 1. Close bleed-type master air valve (B). 3.
Page 8
Repair Spool Repair Kit NXT098 4. Using #2 Phillips screwdriver, remove valve seat (17e) slowly to avoid damaging flutes. Remove valve assembly (17f) and spring (17g). 1. Relieve pressure, page 7. 2. See Parts drawing, page 10. Using a 3/8 in. deep 5.
Page 9
Repair Ball Valve Seal Repair Kit 6. Install the new outboard seal (32b) and inlet NXT097 fitting (32a). 1. Relieve pressure, page 7. The stem seal components (32e-32k) do not need replacement unless leakage is noted. If necessary, 2. See Parts drawing, page 10. Remove the inlet fit- replace parts as shown on page 10.
Parts Parts NXT011 and NXT031 Locking Integrated Air Control Module NXT021 Non-Locking Integrated Air Control Module 20a 20b TI8234d Torque to 140 in-lb (16 N•m). Torque to 500 in-lb (56 N•m). Torque to 240 in-lb (27 N•m). Torque to 130 in-lb (15 N•m).
Schematic Diagram Schematic Diagram Bleed-Type Ball Valve Air Filter AIR IN Quick Air Purge ATMOSPHERE Air Regulator Adjustment Knob Spool TO MOTOR Air Pressure Gauge Overpressure Safety Relief Valve 311239D...
Technical Data Technical Data Maximum air inlet pressure 140 psi (0.97 MPa, 9.7 bar) Maximum regulated working pressure 100 psi (0.69 MPa, 6.9 bar) Maximum operating temperature 140°F (60°C) Air Inlet Size 3/4 npt(f) Air Gauge Port Size 1/8 npt(m) Height 6.5 in.
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.