4.2.
DESCRIPTION OF FUNCTION KEYS
4.2.1. Key HOLD/REL
Pressing key HOLD/REL freezes the value of the measured quantity on the display. After
pressing this key, the message
again to quit the function. To save the value on the display, see § 4.3.4. Key HOLD/REL
also allows quitting the programming menu, going back to the instrument
measuring screen and restores the display
OFF mode. Press longer the HOLD/REL key in order to activate/deactivate the relative
measurement on the selected function (see § 4.3.5).
4.2.2. Key RANGE
Press key RANGE to activate manual mode and disable the Autorange function. The
symbol
Manual Range
"
change measuring range: the relevant decimal point will change its position and the full
scale value in the bargraph will change too. Key RANGE is not active in positions
Type K and 60A
most appropriate ratio for carrying out measurement. If a reading is higher than the
maximum measurable value, the indication
key RANGE for more than 1 second to exit the manual mode and restore the Autorange
mode.
4.2.3. Key MODE/VFD
Pressing key MODE allows selecting a double function on the rotary switch. In particular, it
is active in position
test, capacity test and measurement of resistance, in position TypeK for the selection of
temperature measurement in °C,°F or K, Hz% for the selection of frequency measurement
and duty cycle, VAC+DC
(see § 4.3.3), V
frequency and duty cycle of AC voltage, LoZAC+DC for the selection of AC voltage with
low impedance measurement (see § 4.3.8) "V
1000A
for the selection of AC and DC current measurement for the selection of AC, DC and
A (AC+DC) current measurement. In position
MODE/VFD allows selecting the type of clamp, Standard (
positions VAC+DC
allows to activate/deactivate the VFD (Variable Frequency Driver) measurement mode
(see § 4.3.9) in order to evaluate the AC voltage and current downstream variable
frequency drivers (inverters)
4.2.4. Key IR/
Pressing key IR/
combination multimeter + thermographic image (see § 5.14). Pressing and holding (>2s)
key IR/
(EXCLIPSE) or pressing key
white LED illuminator (see Fig. 2
4.2.5. Key
/INRUSH
Key
/INRUSH, given by the combination of keys
instrument
s programming section in order to set both system parameters and those
'
connected to the detection of the thermographic image (see § 4.3.10).In the positions
60A
, 600A
,1000A
activate/deactivate the AC inrush current of electrical machines with 100ms response time
(see § 5.11).
HOLD
"
appears on the display. In manual mode, press key RANGE to
"
, 600A
, 1000A
CAP
for the selection of measurements for diode test, continuity
for the selection of measurements
Hz% for the selection of AC voltage measurement, AC voltage
, 60A
, 600A
,1000A
(ECLIPSE), Key
(ECLIPSE) allows displaying the multimeter section or the
part 2).
–
the longer press (>2s) of the
appears on the display. Press the key HOLD/REL
"
s illumination with instrument in Auto Power
'
. In Autorange mode, the instrument selects the
OL
appears on the display. Press and hold
"
"
" and "V
, pressing and holding (>2s) key
the longer press (>2s) of MODE/VFD key
(HT9025)
(HT9025) allows turning on/off the internal
and
"
"
EN - 9
ECLIPSE - HT9025
mV
and
V
(AC+DC)
"
"
"
(AC+DC)",60A
, 600A
) or Flexible ( ). In the
, , , , allows entering the
/INRUSH key allows to
s main
'
,
,
"
,