Removing The Electronics - Fein BOZ 32-4M Repair Instructions

Hide thumbs Also See for BOZ 32-4M:
Table of Contents

Advertisement

Rotary Drills
Removal

8.3.2 Removing the electronics

Steps that must be completed:
-
Removing the carbon brushes
Tools:
-
Long-nosed pliers
-
PH2 cross-tip screwdriver
-
Torx T20
1
4
3
C-SC_CSSM
2
5
6
Version 1.0
All rights reserved by FEIN, especially in case of property rights applications.
FEIN retains all rights of disposal, such as copying and circulation.
1.
Remove all plug connections from the electronics.
2.
Unscrew the two screws (1).
3.
Remove the electronics (2).
4.
Unscrew the screw (3).
5.
Remove the cable (4).
6.
Unscrew the two screws (5).
7.
Remove the brush holder (6).
8.
Repeat steps 4 to 7 on the opposite side of the machine.