If the FCB Times are set to 50% of the IN-time they will be 2.5 seconds at an in time of 5 seconds.
If the In-time is changed to 10 seconds, the FCB-times will be 50% of 10 (= 5 seconds).
NOTE
In Congo plays files earlier than Version 4.2, the FCB Delay time was set to
100% due to the fact that Delay Times were inherited from the Delay In
time. These plays (pre-4.2) with FCB Delays set to 100% will be converted to
use a delay of 0s instead.

Default Attribute Time

The Default Attribute Time (3 seconds) is used mainly to keep noise and unnecessary mechanical
friction down when a Moving Device is positioned in the following situations:
When attributes are executed from Independents
When copying Blind attributes to Live
When using Stop table for an old dynamic
When you press Home Attributes
When jumping in the sequence
Using REFRESH in the Main Playback