Si37-701
Ceiling Concealed (Duct) Type (Australia exclusive use)
Model
1 Cooling Capacity (19.5°CWB)
2 Cooling Capacity (19.0°CWB)
3 Heating Capacity
Casing
Dimensions: (H×W×D)
Rows×Stages×Fin Pitch
Coil (Cross
Fin Coil)
Face Area
Type
Motor Output
Fan
Air Flow Rate
External Static Pressure
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
6 Air Filter
Liquid Pipes
Piping
Gas Pipes
Connections
Drain Pipe
Mass (Weight)
7 Sound Level (240V)
Safety Devices
Refrigerant Control
Standard Accessories
Drawing No.
Notes:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp; 35°CDB / Equivalent piping length: 7.5m, level
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp; 35°CDB / Equivalent piping length: 7.5m, level
3 Indoor temp. : 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Equivalent piping length; 7.5m, level difference;
4 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
5 External static pressure is changeable to set by the remote controller this pressure means "High static
6 Air filter is not a standard accessory. A suitable field supplied filter must be installed in the return air duct.
7 The operation sound levels are the conversion values in anechoic chamber. In practice, the sound tend to
Specifications
FXDYQ80MV1
kcal/h
8,000
Btu/h
31,700
kW
9.3
kW
9.0
kcal/h
8,600
Btu/h
34,100
kW
10.0
Galvanized Steel Plate
mm
360×1,168×869
mm
2×18×1.5
0.284
Twin Sirocco Fan
W
290
l/s
590
cfm
1250
Pa
130
5
Direct Drive
Microprocessor Thermostat
for Cooling and Heating
Foamed Polyethylene
φ
mm
9.5 (Flare Connection)
φ
mm
15.9 (Flare Connection)
VP25
mm
(External Dia. 32 Internal Dia. 25)
kg
52
dBA
45
Fuse for PC board,
Fuse for Fan Motor,
Thermal Protector for Fan Motor
Electronic Expansion Valve
Operation Manual,
Installation Manual,
Drain Hose, Hose, Clamps
difference: 0m.
difference: 0m.
0m. (Heat pump only)
pressure - Standard static pressure".
be larger than the specified values due to ambient noise or reflections.
When the place of suction is changed to the bottom suction, the sound level will increase by approx.
5dBA.
FXDYQ100MV1
FXDYQ125MV1
10,000
39,600
11.6
11.2
10,800
42,700
12.5
Galvanized Steel Plate
Galvanized Steel Plate
360×1,478×899
360×1,478×899
2×18×1.5
0.435
Twin Sirocco Fan
Twin Sirocco Fan
490
815
1726
130
5
Direct Drive
Microprocessor Thermostat
Microprocessor Thermostat
for Cooling and Heating
for Cooling and Heating
Foamed Polyethylene
Foamed Polyethylene
φ
φ
9.5 (Flare Connection)
9.5 (Flare Connection)
φ
φ
15.9 (Flare Connection)
15.9 (Flare Connection)
VP25
(External Dia. 32 Internal Dia. 25)
(External Dia. 32 Internal Dia. 25)
61
46
Fuse for PC board,
Fuse for PC board,
Fuse for Fan Motor,
Fuse for Fan Motor,
Thermal Protector for Fan Motor
Thermal Protector for Fan Motor
Electronic Expansion Valve
Electronic Expansion Valve
Operation Manual,
Operation Manual,
Installation Manual,
Installation Manual,
Drain Hose, Hose, Clamps
Drain Hose, Hose, Clamps
4PDA0355
Specifications
FXDYQ145MV1
12,500
14,500
49,500
57,700
14.5
16.9
14.0
16.2
13,800
15,900
54,600
63,100
16.0
18.5
Galvanized Steel Plate
360×1,478×899
3×18×1.5
3×18×1.5
0.435
0.435
Twin Sirocco Fan
490
655
925
1070
1959
2266
100
5
130
Direct Drive
Direct Drive
Microprocessor Thermostat
for Cooling and Heating
Foamed Polyethylene
φ
9.5 (Flare Connection)
φ
15.9 (Flare Connection)
VP25
VP25
(External Dia. 32 Internal Dia. 25)
65
66
48
51
Fuse for PC board,
Fuse for Fan Motor,
Thermal Protector for Fan Motor
Electronic Expansion Valve
Operation Manual,
Installation Manual,
Drain Hose, Hose, Clamps
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
5
33