<Angle parameter input screen>
12) The number of stitches and stitch length can be separately corrected. Push the button , ,
or that corresponds to the target setting item you want to change to select it. Enter your desired
value by pressing
The correction values for inside curve sewing and for outside curve sewing are respectively initial-
ized by pressing the
13) When you press
"2nd sewing screen".
.
and
, the value you have entered is confirmed and the screen returns to the
10) Enter an angle by pressing
(Input the value in increments of 5 °)
*
When you press
you have entered is reset to the initial
value.
11) When you input degree of angle ,
the single-needle sewing condition to
be satisfied to enable sewing of the
entered angle (number of stitches
and stitch length for sewing the
inside curve, and number of stitches
and stitch length for sewing outside
curve) are automatically calculated
based on "S003 Stitch length" and
"Needle gauge setting". For and ,
the reference values for the length of
portion to be sewn with the single nee-
dle using the separately-driven needle
bar function.
.
– 91 –
.
, the value