(2) Setting items for the polygonal-shape stitching steps
Data No.
Item name
Step 01
S201
Step changeover
S203
Sensor value to change over the
step
S204
Number of stitches
(seam length in mm)
S205
Stitch length
(the number of stitches per inch,
the number of stitches per 3 cm)
S206
Needle thread tension (left)
S207
Needle thread tension (right)
S209
Presser foot pressure
S211
Needle bar stop position at the
time of pause
S212
Presser foot lifting during interme-
diate stop
S213
Presser foot lifting during interme-
diate stop
S214
Needle bar stop position at the
time of stop
S215
Stop and presser foot lifting
Unit of
change
Number of
stitches
1
―
1stitch
1 to 2000
0.1mm
-4.0 to 4.0(LH-4578C-0B)
-7.0 to 7.0(LH-4578C-7, LH-4588C-7)
0 to 200
0 to 200
-20 to 200
: Stop with the needle up
: Stop with the needle down
: OFF
0.1mm
0.0 to 20.0
: Stop with the needle up
: Stop with the needle down
: Thread trimming
: Continuity
: OFF
– 61 –
Input range
One-touch
Multi-layered
switch
part
―
1000 to 3000
―
―
: ON
: ON
Separate-
ly-driven nee-
dle bar sensor
―
1 to 2000