No.
U037
Speed during soft start
The number of revolutions set with this memory switch is given precedence
even if it is lower than the lowest speed by pedal.
The initial value varies with the machine head. (0:OFF)
One needle: 170 sti/min Two needles: 200 sti/min
U038
Speed during one-shot stitching
The maximum number of revolutions during soft start differs with the machine
head.
U039
Start position of rotation
Set start position from neutral pedal position. (Pedal Stroke)
U040
Start position of acceleration
Set accelerating position from neutral pedal position. (Pedal Stroke)
U041
Start position of lifting of presser foot
Set work clamp lift position from neutral pedal position. (Pedal Stroke)
U042
Start position of lowering of presser foot
Set work clamp fall position from neutral pedal position. (Pedal Stroke)
U043
Start position of thread trimming
Set thread trimming starting position from neutral pedal position. (Pedal Stroke)
Position that maximum sewing speed is reached
U044
Set maximum speed reaching position from neutral pedal position. (Pedal
Stroke)
U045
Pedal neutral-position correction value
Set neutral position of pedal sensor.
Presser-foot lift finishing position
U047
The position to which the presser foot goes up when the back part of the pedal
is depressed to its first step. (1st-step spring position)
U048
Function of lifting the presser foot by depressing the pedal
Whether or not the presser-foot lifting operation is carried out by depressing the
back part of pedal is set.
0: No operation / 1: Operation
U049
Presser foot lowering time
Time to lower the presser foot is set.
U051
Correction of turning-ON of reverse feed stitching (at start)
U052
Correction of turning-OFF of reverse feed stitching (at start)
Correction of turning-OFF of reverse feed stitching (at end)
U053
U054
Standby time until the presser foot starts going up
Time to be elapsed from the moment the pedal is depressed to the 1st step to
the moment the presser foot starts going up.
Reverse-rotation needle-up after thread trimming
U056
The initial value differs with the machine head.
0: Reverse-rotation needle-up is not performed / 1: Reverse-rotation needle-up
is performed
Item
– 78 –
Setting range
Unit
100 to 3500
sti/min
100 to 3500
sti/min
10 to 1000
-
10 to 1000
-
-500 to -10
-
10 to 500
-
-1000 to -100
-
10 to 15000
-
-150 to 150
-
-1000 to -100
-
0 to 1
-
0 to 500
ms
-50 to 50
Degree
-50 to 50
Degree
-50 to 50
Degree
0 to 200
ms
0 to 1
-