Ametek DR5200 Quick Start Manual page 45

Radar (fmcw) level transmitter for liquids in storage and process applications
Hide thumbs Also See for DR5200:
Table of Contents

Advertisement

OPERATION
4
Procedure
Screen
45
Steps
[> > > > ], [ ] and [> > > > ].
[> > > > ], [^ ^ ^ ^ ], [ ], [ ], [> > > > ] and [^ ^ ^ ^ ].
[> > > > ], [ ] and [> > > > ]
[> > > > ] for the selection of YES or [ ] for the
selection of NO.
Push [> > > > ] after you start equipment in the
tank with parts that move.
[> > > > ] for the selection of "Partially filled" or
[ ] for the selection of "Empty".
[> > > > ] to change the measuring distance.
[> > > > ] to change the position of the cursor.
[ ] to decrease the value or [ ] to
increase the value.
[^ ^ ^ ^ ] to confirm.
[ ] or [ ] to change the parameter
("Maximum" or "Average".
[^ ^ ^ ^ ] to confirm.
www.drexelbrook.com
Description
Default screen.
Enter configuration mode (2.0.0
SUPERVISOR).
Enter the password (the default password is
shown). If it is necessary to change the
password, refer to the handbook.
Push these buttons to start the empty
spectrum recording procedure.
Have you completely filled the tank?
Have you completely filled the tank?
Have you completely filled the tank?
Have you completely filled the tank?
If the tank is full, it is not possible to
complete this procedure. The tank must be
partially filled or empty. Push [> > > > ] to go back
to the start of the empty spectrum recording
procedure.
Please activate moving parts!
Please activate moving parts!
Please activate moving parts!
Please activate moving parts!
If you installed the device on a tank that has
equipment with parts that move (e.g.
agitators), start the equipment.
CAUTION!
CAUTION!
CAUTION!
CAUTION!
Make sure that you start all of the
equipment in the tank with parts that move,
before you continue to the subsequent step.
Is your tank partially filled or empty?
Is your tank partially filled or empty?
Is your tank partially filled or empty?
Is your tank partially filled or empty?
If the tank is partially filled, the device will
scan for the first reflection in the tank.
Continue to the subsequent step. NOTE: If
you set this step to "Partially filled", but the
tank is empty, the device will show the error
message "Failure! Pulse Lost". Push one of
the keypad buttons to go back to the start of
the Snapshot procedure.
If the tank is empty, the scan will start
immediately. Ignore the subsequent step.
Measuring Distance
If the tank is partially filled, type in a
distance shorter than that between the
flange and the tank contents.
Type of empty spectrum
Type of empty spectrum
Type of empty spectrum
Type of empty spectrum
Use the average value for tanks which
contain fixed objects only. Use the
maximum value for tanks which contain
many objects or moving objects.