Empty Spectrum Recording - Ametek DR5200 Quick Start Manual

Radar (fmcw) level transmitter for liquids in storage and process applications
Hide thumbs Also See for DR5200:
Table of Contents

Advertisement

DR5200
Screen

4.4 Empty spectrum recording

The empty spectrum recording procedure is important for the performance of the device. We
recommend that the tank is empty or only filled to the minimum level before you do the
procedure.
Use this procedure (menu item 2.1.2 EMP.SPEC.REC.) if there are fixed and moving objects in the
tank that can cause parasitic signals. The device does a scan for objects that do not change their
vertical positions in the tank (heating tubes, agitators, fuel assemblies etc.) and records the
data. The device can then use this data to put the measurement signal through a filter (empty
spectrum).
When the empty spectrum filter is on (when menu item 2.3.12 EMP.SPEC.EN. is set to "on"), it
will ignore the parasitic signals. Because the device records the data from the procedure, it is
also not necessary to do the procedure again if you de-energize the device.
CAUTION!
Make sure that the tank is empty or only filled to the minimum level.
Before you do the empty spectrum recording procedure, install the device on the tank. For more
data about how to install the device, refer to the handbook.
Values and parameters that can be changed are shown between the « ... » marks in the
illustrations that follow. Push the keypad buttons in the correct sequence:
DR5200QS-LM, EDO#6-13-112 - Issue #3
Steps
[> > > > ] to change the tag name.
[> > > > ] to change the position of the cursor.
[ ] to decrease the alphanumeric value
(A, B, ..., 1, 2, ...) or [ ] to increase the
alphanumeric value.
[^ ^ ^ ^ ] to confirm.
2 × [^ ^ ^ ^ ] to confirm.
[ ] or [ ] for the selection of the save
option (STORE NO or STORE YES).
[^ ^ ^ ^ ] to confirm.
www.drexelbrook.com
OPERATION
Description
The device has an identification code (tag
name). The supervisor can enter a
maximum of 8 numbers or letters.
Set to STORE YES to save and use the data.
Set to STORE NO to cancel the changes to
the device settings.
4