Ametek DR5200 Quick Start Manual page 33

Radar (fmcw) level transmitter for liquids in storage and process applications
Hide thumbs Also See for DR5200:
Table of Contents

Advertisement

ELECTRICAL CONNECTIONS
3
3 Remove the cover.
Figure 3-3: Procedure for electrical installation
Equipment needed:
• Small slotted tip screwdriver (not supplied)
Procedure:
1 Do not disconnect the safety cord from the terminal compartment cover. Put the terminal
compartment cover adjacent to the housing.
2 Remove the connector from the circuit board.
3 Connect the electrical wires to the connector. Attach the connector to the circuit board. Tight-
en the cable entry glands.
Close the terminal compartment cover
Figure 3-4: How to close the terminal compartment cover
• Put the cover on the housing and push it down.
• Turn the cover clockwise until it is fully engaged.
• Tighten the lock screw.
33
www.drexelbrook.com
DR5200
DR5200QS-LM, EDO#6-13-112 - Issue #3

Advertisement

Table of Contents
loading