DR5200
Metallic Horn and Wave Guide: compact and remote versions with the high-
temperature (HT) extension
Ambient temperature / flange temperature, flange and threaded connection, in °C
Figure 2-17: Ambient temperature / flange temperature, flange and threaded connection, in °C
Ambient temperature / flange temperature, flange and threaded connection, in °F
Figure 2-18: Ambient temperature / flange temperature, flange and threaded connection, in °F
1 Maximum ambient temperature, °C
2 Maximum flange temperature, °C
3 Maximum ambient temperature, °F
4 Maximum flange temperature, °F
5 Compact and remote versions of the device with the Metallic Horn or Wave Guide antenna, the HT extension and EPDM
and PFA gaskets
6 Compact and remote versions of the device with the Metallic Horn or Wave Guide antenna, the HT extension and a PFA
gasket
INFORMATION!
When the process temperature is -50
de-rating for the ambient temperature. The minimum ambient temperature is -39
When the process temperature is -60
rating for the ambient temperature. The minimum ambient temperature is -37
DR5200QS-LM, EDO#6-13-112 - Issue #3
C / -58
F and the device has an EPDM gasket, there is a
°
°
C / -76
F and the device has a PFA gasket, there is a de-
°
°
www.drexelbrook.com
INSTALLATION
°
C / -38.2
C / -34.6
F.
°
°