SATEL
"Yes" (the control panel will only wait 10 seconds after power-up for the firmware
replacement to begin). Then the replacement of control panel firmware will start.
2. Programming
The alarm control panel may be configured for operation by using the keypad (locally) or
the computer with the D
2.1
Keypad
Programming is only possible when the control panel is accessible to the installer. By default,
the
P
ERMANENT
5. S
.
).
ERV
ACCESS
DOWNLOAD/SERVICE right can disable the P
each time the duration of service access to the control panel ([code]
6. A
).
CCESS TIME
Programming the control panel from keypad is carried out by using the functions grouped in
the service mode menu. Access to the menu, submenus and particular functions is facilitated
by numerical shortcuts. In case of the LED keypad, programming is subject to some
limitations (e.g. entering names is impossible). SATEL recommends that the LCD keypad
be used for programming the control panel.
The service mode is indicated on the keypads by means of the blue
lit on the keypad in which the service function menu is available, while it is blinking on all the
other keypads connected to the control panel. The service mode may also be signaled
acoustically, after the corresponding option is enabled. Additional information is provided by
the
LED, which is:
– blinking during navigation throughout the menu and submenus;
– lit when any service function is running.
When in the service mode, the alarm system signals no alarms.
2.1.1 Starting the service mode
1. Enter the service code (by default: 12345) and press the
2. Press in turn the
2.1.2 Starting the service mode "from pins"
If entering the service mode in the normal way is impossible, you can use the emergency
hardware procedure, so-called starting "from pins".
1. Power down the control panel (first, switch off power in the 230 V AC circuit, to which the
control panel transformer is connected, and then disconnect the battery).
2. Place a jumper across the RESET pins on the control panel mainboard.
3. Power up the control panel (first, connect the battery, and then switch on power supply in
the 230 V AC circuit, to which the control panel transformer is connected).
4. Wait a few seconds and remove the jumper from the RESET pins.
5. On the keypad with the lowest address, the
blinking, indicating that the service menu is available on the keypad (in case of the LCD
keypad, the menu will be displayed). On the other keypads, the
blinking.
X program installed (locally and remotely).
LOAD
SERVICE
ACCESS
After
the
installation
keys to start the service mode.
VERSA
option
is
enabled
is
completed,
ERMANENT SERVICE ACCESS
LED will light up and the
0. S
([code]
the
user
having
option and define
0. S
LED. The
key.
LED will start
LEDs will start
5
ERVICE
the
ERVICE
LED is
Need help?
Do you have a question about the VERSA and is the answer not in the manual?
Questions and answers