Before you start programming, please read carefully this manual in order to avoid mistakes that can lead to malfunction or even damage to the equipment. SATEL's goal is to continually upgrade the quality of its products, which may result in alterations of their technical specifications and firmware. The current information on the introduced modifications is available on our website.
CONTENTS Introduction........................4 Configuring the control panel with keypad ..............4 Starting the service mode....................... 4 Starting the service mode “from pins” ..................4 Navigating through the menu and running functions.............. 5 2.3.1 Using the arrow keys ........................5 2.3.2 Using the digit shortcuts ........................5 “Step by step”...
Page 4
VERSA Plus SATEL Output S.........................50 Configuring the output S ...................... 50 Output S parameters......................50 Devices ..........................50 Configuring the devices ....................... 50 Built-in communication modules (VERSA-ETH) ..............51 9.2.1 Ethernet communication module (ETHM) ..................52 9.2.2 GSM communication module ......................53 Keypad..........................
Page 5
SATEL VERSA Plus 13.1 Configuring the SMS control ....................84 13.2 Parameters of SMS control ....................84 14. User schedules ......................85 14.1 Configuring the user schedules.................... 86 14.2 Parameters of the user schedule ..................86 14.3 Functions assigned to keyfob buttons .................. 87 14.4...
VERSA Plus SATEL 1. Introduction The VERSA Plus alarm system can be configured by using: keypad, computer with D X program installed (locally or remotely). LOAD Local programming (using the keypad or D X program) is possible, if one the following...
SATEL VERSA Plus If the S RESET option is disabled in the control panel then, ERVICE MODE FROM PINS depending on the type of keypad in which the lowest address is set: LCD: the LEDs of the second partition will be lit, and the message “Restore factory settings ? 1=Yes”...
VERSA Plus SATEL LEDs of the first and second partition show the number of programming step (see: page 9 table 4). Some programming steps may be sometimes not available. Entering data The changes entered will be saved after pressing the key.
Page 9
SATEL VERSA Plus Characters available after next keystroke mode [ABC] mode [abc] Table 1. Characters available in the keypad when entering telephone numbers (to change the letter case, press Special character Function description switch-over to pulse dialing switch-over to tone dialing (DTMF)
VERSA Plus SATEL Characters available after next keystroke " & < > Table 3. Characters available when entering names. The upper case letters are available under the same keys (to change the letter case, press 2.5.2 LED keypad The data being entered are presented by means of LEDs. The method of programming depends on the type of data to be entered by service function.
Page 11
SATEL VERSA Plus LED status Digits and characters – LED OFF – LED ON Table 4. The binary mode of presenting digits and characters. Fig. 1. Examples of presenting decimal values by means of LEDs in the LED keypad. Value...
VERSA Plus SATEL Fig. 2. Examples of presenting hexadecimal values by means of LEDs in the LED keypad. Two-character value D5 is programmed in Example A, and four-character value E92B in Example B. Programming telephone numbers The telephone numbers are entered in much the same way as in the LCD keypad, however the LEDs can only present the first 6 characters (only digits and characters B, C, D, E and F –...
VERSA Plus SATEL Exiting the service mode In order to exit the service mode, use the S function. ODE END To exit the service mode, do the following: LCD keypad: keep pressing until you return to the main menu, and then press in turn...
Page 19
SATEL VERSA Plus click to open the “Versa – Outputs” window. click to open the “Versa – Timers” window. click to open the “Versa – Reporting” window. click to open the “Versa – Tel. messaging” window. click to open the “SMS control” window.
VERSA Plus SATEL Fig. 4. Menu displayed after pressing the button. 3.1.2 Changing the DloadX program access code 1. Click on “File” “Access setup” “Change access code” (Fig. 5). Dialog window with a field for entering the code will be displayed.
SATEL VERSA Plus Parameters related to communication between the control panel and DloadX program 3.2.1 Communication identifiers Communication identifiers are necessary for all methods of communication. Programming the communication identifiers You can program the communication identifiers: D X program: “Identifiers and tel. no” window (the command for opening this window is LOAD available in the “Communication”...
Page 22
VERSA Plus SATEL Control panel settings You can configure the modem communication settings: when programming the global parameters (see: “Global parameters” p. 30). when programming the built-in communication modules (see: “Built-in communication modules (VERSA-ETH)” p. 51). Description of parameters Telephone numbers Descriptions displayed on the LCD keypad are shown in square brackets.
D X program via Ethernet / GPRS. LOAD ETHM-1 ID – individual identification number of the control panel for the purpose of communication via the SATEL server. ETHM-1 MAC – hardware address of built-in Ethernet module.
VERSA Plus SATEL Control panel settings For parameters and options related to communication via Ethernet / GPRS, see section “Built-in communication modules (VERSA-ETH)” (p. 51). Local programming 3.3.1 Starting local programming 1. Connect the control panel USB port with the computer port.
Page 25
X program main menu. A drop down menu will be LOAD displayed. 2. Click “VERSA Plus – GSM modem”. Window with modem initialization information will be displayed. 3. After modem initialization, click on the “Connect” button. Information on connection establishment will be displayed.
Page 26
X program m ain menu. A drop down menu will be LOAD displayed. 2. Click “VERSA Plus – GSM modem”. Window with modem initialization information will be displayed. 3. After mode m initialization, click on the “Connect” button. Information on connection...
Page 27
SATEL VERSA Plus 4. The control panel will receive the call, but will hang up. The D X program will inform LOAD you that the control panel will call back. 5. The control panel will call back the number of computer modem (the number for communication via GSM comm unicator).
X program main menu. A drop down menu will be LOAD displayed. 2. Click “VERSA Plus – G SM modem”. Window with modem initialization information will be displayed. 3. Ask the user to start the GSM CSD function (he is supposed to enter the code and press , and then press in turn ).
Page 29
X program must have a public IP address. LOAD 4. Establishing connection via the SATEL server. The control panel can be programmed from any location. No public IP address is required for the control panel or the computer with D X program.
Page 30
Having received the SMS message, the control panel will connect to the indicated twork address. 5. W hen communication is established, the D X program will inform you about it. LOAD unication via the SATEL server l panel settings: ena ble D X->ETHM-1 and S options (see: “Ethernet...
D X program main menu. A drop down menu will be LOAD displayed. 2. Click “TCP/IP: Satel server”. The “Con nection TCP/IP: DloadX <-> ETHM-1” window will be displayed. 3. Click on the “Connect” button in the “Connection TCP/IP: DloadX <-> ETHM-1” window.
VERSA Plus SATEL program the control command that will be sent in the SMS message to initiate communication betwe en control panel and D X program (see: “Built-in communication LOAD modules (VERSA-ETH)” p. 51), configure the built-in GSM module (see: “GSM communication module” p. 53).
Page 33
SATEL VERSA Plus Answering – modem – if the option is enabled, external initiation of the modem communication with the control panel is possible. uble call – the option applies to the analo g telephone communicator. If enabled, you must call the control panel twice to be connected.
Page 34
VERSA Plus SATEL Serial data on OUT 3/4 – if the option is enabled, OUT3 and OUT4 outputs send the system status data (zone alarms, fire alarms, troubles, armed modes, etc.) and do not execute any other programmed functions. The outputs may be used to control the NR2-DSC radio monitoring transmitter (NEMROD system –...
Page 35
SATEL VERSA Plus Tamper alarm always audible – if the option is enabled, the tamper alarm will be signaled always on outputs with the 1. E and 2. I functions (if the XTERNAL SIREN NTERNAL SIREN option is disabled, only in armed mode). Also, lack of the expander is always saved in the event log as a tamper alarm.
VERSA Plus SATEL Answering/remote control when armed partition 1 / 2 – if the option is enabled, telephone answering and remote control features are only available when selected partitions are armed. Additionally, the list of global options in the keypad includes: ...
SATEL VERSA Plus User code min. lenght – the minimum number of characters required for the control panel to accept a new code or a changed code. This parameter will be included when creating and editing the codes (it is irrelevant to the codes already existing in the system).
Page 38
VERSA Plus SATEL Using the keypad, you can arm the system without the exit delay, if the hold down the key which ends the arming sequence ( ) for approx. 3 seconds. Fig. 7. D X program: configuring partition parameters in the “Versa – Structure” window.
1 to 30 range. You can do it in the following manner: D X program: “Versa – Structure” window “Hardware ” tab “Versa Plus: [system LOAD name]” branch, keypad: S 2. H I...
VERSA Plus SATEL You can program the value 0 for the resistor R2. In the 2EOL configuration you must use then two resistors, the resistance value of each being equal to half the value defined for the resistor R1. In the EOL configuration, the resistance value is equal to the sum of values programmed for the resistors R1 and R2.
SATEL VERSA Plus Zone parameters Zone name – individual name of zone (up to 16 characters). Partition 1 / Partition 2 – partition to which the z one is assigned. The zone must be assigned at least one partition, for its status to be supervise Fig.
Page 42
VERSA Plus SATEL In the LCD keypad, the E and W NTRY DELAY ELAY ACTIVATION TIME AITING TIME parameters are programmed as the A LARM DELAY Arm mode – the armed mode activated after violating the 13. A or 14. A...
SATEL VERSA Plus – Vibration – the pulse whose duration is equal to or longer than the defined time will cause violation of the zone. Values from the 3 ms to 96 ms range can be programmed (every 3 ms).
VERSA Plus SATEL – permanently armed zone for calling medical assistance. 9. 24 H MEDICAL – dedicated, permanently armed zone for operating fire detectors. 10. 24 H FIRE – permanently armed zone for antimasking control. Violation of the zone 11. D ETECTOR MASK is interpreted by the control panel as a detector trouble.
Page 45
SATEL VERSA Plus Warning alarm in the partial armed mode will work irrespective of the W ARNING ALARM global option, which refers to the delay of loud signaling and reporting if any mistakes are made when entering into the protected facility.
VERSA Plus SATEL belongs is armed. The option is available when the S option is TORE TO EVENT LOG enabled. Keybox control – an option for the 12: N zone type. If this option is enabled, O ALARM ACTION violation of the zone will result in logging an event which informs that the keybox is open.
SATEL VERSA Plus 4. Triggering zones [the partition armed mode is selected for the outputs with functions 18. A and 20. A , and the troubles for the output with RMED STATUS LARM ARM STATUS function 19. T (see: Section O...
VERSA Plus SATEL Output parameters Fig. 10. D X program: “Versa – Outputs” window. LOAD Output name – individual name of the output (up to 16 characters). Cut-off time – time during which the alarm outputs and the outputs with functions 13. Z , 14.
SATEL VERSA Plus 2. Battery trouble – control panel mainboard 3. Telephone line – no voltage 4. Telephone line – no dial tone 5. OUT1 output trouble 6. OUT2 output trouble 7. KPD output trouble 8. AUX output trouble 9. Reporting trouble – monitoring station 1 10.
Page 50
VERSA Plus SATEL – 21. D – the output activates for a preset time, when the arming ETECTORS RESETTING procedure is initiated in the selected partition (without taking into account the exit delay). The users authorized to access the given partition can activate the output by using the function.
Cut off time – period of time during which the output is active. Signaling mode – type of audible signaling. 9. Devices The VERSA Plus control panel has built in: Ethernet communication module, GSM communication module, voice module.
SATEL VERSA Plus You can configure the devices as follows: D X program: “Versa – Structure” window “Hardware” tab. The list of devices is LOAD presented in the form of tree structure on the left side of the window (Fig. 12). Click on the name of device you want to configure.
If value 0 is programmed, the communication test is disabled. Satel server – if this option is enabled, communication with the module can be effected via the SATEL server. For communication vie the SATEL server, you do not need to additionally configure the network device through which the module connects to the public network.
SATEL server. Having deleted the old ID number, the control panel will receive a new one. The VERSA Control applications using the old ID number will be unable to connect to the control panel.
Page 56
VERSA Plus SATEL Fig. 14. D X program: configuring the built-in GSM module. LOAD Lock time – the time during which switch-over to the other SIM card is impossible. For reporting, the transmission paths programmed as subsequent ones, if they require switch- over to the other card, will be skipped during the lock lime countdown (see: “Transmission...
Page 57
SATEL VERSA Plus operator to the phone number from which the SMS message with control command was sent. You can enter up to 8 alphanumeric characters (you can use spaces, but at least one character must be different from the space). Owing to the USSD codes you can, for example, check the account balance of SIM card installed in the control panel.
VERSA Plus SATEL Keypad 9.3.1 Parameters and options Descriptions displayed on LCD keypad are shown in square brackets. CHIME signal of zones [Zone chime] – the keypad can audibly signal violation of selected zones. If the zone is armed, violation will not trigger the CHIME signal.
Page 59
SATEL VERSA Plus Quick arming – Partition 1 [Part.1 QuickArm] – if this option is enabled, partition 1 can be armed without entering the code. The quick arming is not possible, if the G 2 option is RADE enabled in the control panel.
VERSA Plus SATEL The messages are presented on the display of LCD keypad. The messages will not be displayed, if the G 2 global option is enabled. RADE 9.3.2 Volume The volume level for different events is configurable in the case of VERSA-LCDM and VERSA-LCDM-WRL keypads.
Page 61
SATEL VERSA Plus can work within each other's operating range (12 seconds – up to 150, 24 seconds – up to 300, 36 seconds – up to 450). Beyond the response period, information about tampers of devices and violations of detectors operating in active mode are sent to the controller. The response period has an effect on the level of energy consumption by the wireless devices.
VERSA Plus SATEL The test mode is started/ended during polling, which results in a delay, its duration depending on the programmed response period. The test mode will be turned off automatically after 30 minutes of: – starting the test mode from the D...
SATEL VERSA Plus the way of operation in test mode. APD-100 – wireless passive infrared detector. The following is to be programmed: sensitivity, option of immunity to pets up to 15 kg. ARD-100 – wireless reorientation detector. Sensitivity is to be programmed.
Page 64
VERSA Plus SATEL digit – pulse validity: 0 (30 seconds), 1 (120 seconds), 2 (240 seconds) or 3 (unlimited duration). APMD-150 – enter 3 digits: digit – sensitivity of infrared path: from 1 to 4 (1 – minimum; 4 – maximum).
Page 65
SATEL VERSA Plus 3. Enter a digit from the 1 to 3 range to define sensitivity (1 – low, 2 – medium, 3 – high), and then press AMD-100 / AMD-101 magnetic contact 1. Enter a number from the 0 to 50 range to define the rules of device presence control, and then press 2.
Page 66
VERSA Plus SATEL ARD-100 detector 1. Enter a number from the 0 to 50 range to define the rules of device presence control, and then press 2. Press any numeric key to define whether the detector is to be always active ( – no, –...
SATEL VERSA Plus ASW-100 E / ASW-100 F controller 1. Enter a number from the 0 to 50 range to define the rules of device presence control, and then press 2. Use the keys to define mode of operation of the button (“inactive” – the electric circuit is controlled remotely only;...
Page 68
VERSA Plus SATEL ABAX wireless sirens The wireless sirens take up 2 outputs and 2 zones in the system. How the signaling is controlled by the outputs depends on the siren: ASP-105 – the first of the outputs to which the siren is assigned controls the acoustic signaling.
SATEL VERSA Plus The EN50131-3 standard requires that zones must react to signals lasting more than 400 ms. It means in case of the wireless expanders of hardwired zones and outputs that no values exceeding 300 ms should be entered when programming the sensitivity (the higher the value, the lower the sensitivity).
VERSA Plus SATEL Fig. 18. D X program: configuring the 433 MHz wireless system controller and 433 MHz LOAD wireless detectors. LCD keypad You can enable/disable the presence control option: immediately after adding a detector to the system (for the procedure of adding 433 MHz...
SATEL VERSA Plus energy save (available in some detectors) – after sending information on violation, the detector will not send any further information about violations for 3 minutes (the zone will be violated for 2 seconds after the controller receives the transmission containing information on detector violation).
VERSA Plus SATEL 10. Timers The timer compares the time to that of the control panel clock and executes the selected function at the programmed time. Using the timers, it is possible to control the armed mode of partitions and the outputs 15. C .
SATEL VERSA Plus 10.2 Timer parameters Name – individual timer name (up to 16 characters). Weekly schedule – the time of starting/ending timer for each day of the week and everyday (the timer can be started/ended twice a day: according to the settings scheduled for the given day of the week and according to the everyday settings).
VERSA Plus SATEL Events amount limiting – if the option is enabled, events from the same source are saved into the event log and reported to the monitoring station 3 times only. This option does not apply to the alarms from zones (see: A 3 or A 1 zone option).
Page 75
SATEL VERSA Plus The identifier consists of 4 hexadecimal characters (digits or letters from A to F). Entering the value 0000 means that events assigned to that identifier will not be reported. Using the digit 0 in the identifiers is not recommended.
VERSA Plus SATEL Station 1 options / Station 2 options SIA – send part. name – if the option is enabled, in the SIA format, the name of partition where the event took place will also be sent, in addition to the event code.
Page 77
SATEL VERSA Plus In the case of SMS reporting, the control panel gets no acknowledgement of receiving the event codes by the monitoring station, hence this transmission path should be used as the last one. The switch-over from one SIM card to the other one requires time (for example, to log onto the network), so it is better to use up all the transmission paths available for one SIM card.
X program: “SIA-IP” tab in “Versa – Reporting” window. LOAD IP format – if the event codes are to be sent via Ethernet or GPRS, specify whether SATEL format or SIA-IP format (SIA DC-09 standard) will be used. Protocol – if the event codes are to be sent via Ethernet or GPRS, specify whether TCP or UDP protocol will be used.
SATEL VERSA Plus hex – if the option is enabled, you can enter up to 32 hexadecimal characters as the SIA-IP . If the option is disabled, you can enter up to 16 hexadecimal characters as the SIA-IP SIA-IP acct – a string of up to 16 hexadecimal characters, which is used to identify the control panel for the purpose of reporting in SIA-IP format.
TATION KEY – control panel identifier for the purposes of monitoring via Ethernet/GPRS (ETHM/GPRS 3. Define whether the events are to be sent in SATEL format or SIA-IP format (IP FORMAT 4. If the SIA-IP format is to be used, configure the additional options and parameters (S...
VERSA Plus – control panel identifier for the purposes of monitoring via Ethernet/GPRS (ETHM/GPRS 3. Define whether the events are to be sent in SATEL format or SIA-IP format (IP FORMAT 4. If the SIA-IP format is to be used, configure the additional options and parameters (S...
VERSA Plus SATEL Fig. 24. D X program: configuring the telephone messaging parameters. LOAD 12.1.2 Parameters and options of the telephone messaging option is described in “Global options” section (p. 30). ELEPHONE MESSAGING Round count – the number of attempts made by the control panel to notify the selected telephone number about the event.
SATEL VERSA Plus number of the message to be sent. You can assign the text message number to an event. In the case of voice notifications, the voice message assigned to that text message will be used. 12.1.4 SMS/Pager messages You can program up to 64 text messages that will be used for PAGER or SMS notification.
VERSA Plus SATEL 2. Configure the global options related to analog communicator telephone: – determine how the telephone numbers should be dialed (T ; in case of the ONE DIALING pulse dialing option – P 1/1,5 ( 1/2)), ULSE – determine whether the control panel, prior to dialing the number, should check the...
Page 85
SATEL VERSA Plus Fig. 25. D X program: configuring the e-mail messaging. LOAD SMTP account Fig. 26. D X program: entering the data of e-mail account that will be used for e-mail LOAD messaging. The presented settings are just an example.
VERSA Plus SATEL Encryption – you can define if and how the outgoing mail is encrypted: none – outgoing mail is not encrypted. STARTTLS – outgoing mail will be encrypted using the STARTTLS protocol. SSL/TLS – outgoing mail will be encrypted using the SSL/TLS protocol.
SATEL VERSA Plus Fig. 27. D X program: “SMS control” window. LOAD Function – the function that will be started after the built-in GSM module receives an SMS message containing control command to which the function is assigned. To select the function: 1.
VERSA Plus SATEL 14.1 Configuring the user schedules You can configure the user schedules: D X program: “Versa – Users” window “Users Schedules” tab (Fig. 28). LOAD functions available in the U submenu (S 8. U SR TEMPLATES...
SATEL VERSA Plus Right – defines which functions are available to the user. The following rights are available: Arming – the user can arm the system. Disarming – the user can disarm the system. Alarm clearing – the user can clear alarms.
Page 90
VERSA Plus SATEL 5. Zone 5 violation 6. Zone 6 violation 7. Zone 7 violation 8. Zone 8 violation 9. Zone 9 violation 10. Zone 10 violation 11. Zone 11 violation 12. Zone 12 violation 13. Zone 13 violation 14. Zone 14 violation 15.
VERSA Plus SATEL 8. Output 8 state 9. Output 9 state 10. Output 10 state 11. Output 11 state 12. Output 12 state 13. Arming: Partition 1 LED is lit when partition 1 is armed 14. Arming: Partition 2 LED is lit when partition 2 is armed 15.
VERSA Plus control panel, this button functionality is not used. click to interrupt / resume the connection. The meaning of button icon color: green – connection OK gray –...
VERSA Plus SATEL User – if this field is selected, the message presented in the field next to it must be synthesized. The message content is editable. The content of messages included in the “Menu” group is defined by the manufacturer and cannot be edited.
Page 95
SATEL VERSA Plus Outputs OFF – click on the button to select the outputs that are to be deactivated after running the macro. You can control the 15. C type outputs. ONTROLLED Partitions Disarm – click on the button to select the partitions which are to be disarmed after running the macro.
VERSA Plus SATEL 15.1.5 “Names: INT-VG / Control panel” tab Messages from the “Names” group and notification messages are presented in the tabs. Next to each message, a name or notification message from the control panel may be displayed. The data from control panel are presented, if one of the following conditions is met: ...
15 minutes (which requires suitable configuration of the cut-off time of alarm signaling outputs). 17. Control panel firmware update 1. Download the update program for control panel firmware from www.satel.eu. 2. Connect the control panel USB port with the computer port. 3. Run the update program for control panel firmware.