VPN tunnel between SCALANCE M-800 and security CPs
4.2 Secure VPN tunnel with PSK
4.2.3.5

Configuring phase 1 and phase 2

Configuring phase 1
1. Click on "Security" > "IPSecVPN" in the navigation area and on the "Phase 1" tab in the
content area.
2. For "DPD", select "restart".
3. Configure phase 1 with the following settings from the configuration file:
4. Click "Set Values".
Configuring phase 2
1. Click the "Phase 2" tab.
2. Configure phase 2 with the following settings from the configuration file:
3. Click "Set Values".
160
Encryption
Authentication
IKE Key Derivation
Lifetime [min]
DPD timeout [sec]
Aggressive Mode
Encryption
Authentication
IKE Key Derivation
Lifetime [min]
3DES
SHA1
DH group 2
1440
60
no
3DES
SHA1
DH group 2
1440
Getting Started, 06/2015, C79000-G8976-C337-04