6.1.2

Creating NETMAP rules

Requirement
● The VPN connection M876_to_M816 is configured, see Creating a VPN connection
(Page 207).
Procedure
1. Click on "Layer 3" > "NAT" in the navigation area and on the "NETMAP" tab in the content
area.
2. Specify the NETMAP rule
3. Click "Create". A new row is created in the table with the settings.
4. Specify the NETMAP rule
5. Click "Create". A new row is created in the table with the settings.
6. Click "Set Values".
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04
Type
Source Interface
Destination Interface
Source IP Subnet
Translated Source IP Subnet
Destination IP Subnet
Type
Source Interface
Destination Interface
Source IP Subnet
Destination IP Subnet
Translated Destination IP Subnet
for the outgoing queries with the following settings:
Source
vlan1
IPSec M876_to_M816
192.168.20.0/24
192.168.200.0/24
192.168.10.0/24
for the incoming queries with the following settings:
Destination
IPSec M876_to_M816
vlan1
192.168.10.0/24
192.168.200.0/24
192.168.20.0/24