Downloading The Configuration To The Cp And Saving The M-800 Configuration - Siemens SCALANCE M-800 Series Getting Started

Simatic net industrial remote communication
Hide thumbs Also See for SCALANCE M-800 Series:
Table of Contents

Advertisement

VPN tunnel between SCALANCE M-800 and security CPs
4.3 Secure VPN tunnel with certificates
4.3.2.3

Downloading the configuration to the CP and saving the M-800 configuration

Downloading the configuration to the CP
1. Close the Security Configuration Tool.
2. In HW Config, select the "Station" > "Save and Compile" menu.
3. Download the new configuration to the security module using the "PLC" > "Download to
Module ..." menu.
– For CP 1628: If the download was completed free of errors, the security module
– For CP 343-1 Advanced or CP 434-1 Advanced: Restart the S7 CPU following the
Saving the SCALANCE M-800 configuration
1. In the content area, select the "M-800" and select the menu command "Transfer" > "To
module(s) ...".
2. Save the configuration file "Projectname.M-800.txt" in your project folder and assign a
password for the private key of the certificate, e.g. Di1S+Xo?.
Result
The following files will be saved in the project directory:
● Configuration file: projectname.M-800.txt
● Remote certificate: Projectname.group1.CP.cer
The configuration file contains the exported configuration information for the SCALANCE M-
800 including information on the additionally generated certificates. Follow the instructions in
the configuration file.
172
restarts automatically and the new configuration is activated.
download, to activate the new configuration.
PKCS12 file: projectname.string.M-800.p12
SCALANCE M-800 Getting Started