Connecting SCALANCE M-800 to WAN
1.3 Connecting M826 with SHDSL
1.3.2.2

Setting up SCALANCE M826 and network

Note
Familiarize yourself with the security instructions before you commission the device. You will
find the security instructions in the operating instructions.
Procedure
1. First unpack the M826 and check that it is undamaged.
2. Fit the power supply.
3. Wire up the M826, see Setup (Page 50).
4. Connect the device to the local network via the Ethernet ports.
5. Turn the device on. After connecting up, the fault LED (F) is lit red.
6. Now, turn on the PC.
1.3.2.3

Configuring the SCALANCE M826 with the PST

Requirement
● The devices are in the same IP subnet.
● The IP addresses are unique.
Procedure
1. Start the Primary Setter Tool with "Start > SIMATIC > Primary Setup Tool".
If several network adapters are installed in the PC, select the network adapter connected
to the M826 in "Settings > Network adapter".
2. Click on the magnifier in the toolbar to start the search. Following the search, the M826 is
listed in the PST.
52
WARNING
Use safety extra-low voltage only
The SCALANCE M826 is designed for operation with safety extra-low voltage. This
means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/
VDE0805 can be connected to the power supply terminals.
The power supply unit for the SCALANCE M826 power supply must meet NEC Class 2,
according to the National Electrical Code(r) (ANSI / NFPA 70).
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04