Connecting SCALANCE M-800 to WAN
1.3 Connecting M826 with SHDSL
Steps in configuration
1. Setting up SCALANCE M826 and network (Page 64).
2. Configuring the SCALANCE M826 with the PST (Page 65)
3. Launching Web Based Management (Page 67)
4. Logging in to Web Based Management (Page 69)
5. Configuring SCALANCE M826.
The steps are the same for all devices, the only difference being the settings.
– Specifying device information (Page 70)
– Setting the time (Page 71)
– Creating IP subnets (Page 73)
– Configuring SHDSL (Page 75)
– Configuring routes (Page 77)
– Allow access (Page 78)
1.3.3.2

Setting up SCALANCE M826 and network

Note
Familiarize yourself with the security instructions before you commission the device. You will
find the security instructions in the operating instructions.
Procedure
1. First unpack the M826 and check that it is undamaged.
2. Fit the power supply.
3. Wire up the M826, see Setup (Page 62).
4. Connect the device to the local network via the Ethernet ports.
5. Turn the device on. After connecting up, the fault LED (F) is lit red.
6. Now, turn on the PC.
64
WARNING
Use safety extra-low voltage only
The SCALANCE M826 is designed for operation with safety extra-low voltage. This
means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/
VDE0805 can be connected to the power supply terminals.
The power supply unit for the SCALANCE M826 power supply must meet NEC Class 2,
according to the National Electrical Code(r) (ANSI / NFPA 70).
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04