The configuration of the tunnel connection is complete.
3.3.2.3

Configuring the properties of the S612

Since the S612 is connected to the Internet via a DSL router, the properties of the S612
must be configured accordingly.
Procedure
1. Select the "S612" in the content area.
2. Select the menu command "Edit" > "Properties". Click the "Routing" tab.
3. For "Default router", enter the internal IP address of the default router "192.168.184.254".
Click "Apply"
4. Click the "VPN" tab.
5. For "Permission to initiate connection establishment", select the "Wait for partner
(responder)" entry.
6. Enter the WAN IP address of the DSL router, e.g. 91.19.6.84