1.1.2

Setting up SCALANCE M874 and network

Note
Familiarize yourself with the security instructions before you commission the device. You will
find the security instructions in the operating instructions.
Procedure
1. First unpack the M874 and check that it is undamaged.
2. Insert the SIM card.
3. Fit the power supply.
4. Fit the antenna.
5. Connect the PC to one of the two Ethernet ports (P1, P2).
6. Turn the device on. After connecting up, the fault LED (F) is lit yellow.
7. Now, turn on the PC.
1.1.3

Launching Web Based Management

In the factory settings, the SCALANCE M-800 can be reached at the following IP address:
● IP address: 192.168.1.1
● Subnet mask: 255.255.255.0
In this configuration example, the Admin PC has the following IP address setting to allow it to
access the Web Based Management of the M-800.
IP address
192.168.1.20
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04
WARNING
Use safety extra-low voltage only
The SCALANCE M874 is designed for operation with safety extra-low voltage. This
means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/
VDE0805 can be connected to the power supply terminals.
The power supply unit for the SCALANCE M power supply must meet NEC Class 2,
according to the National Electrical Code(r) (ANSI / NFPA 70).
Connecting SCALANCE M-800 to WAN
1.1 Connecting M874 with the mobile wireless network
Subnet mask
255.255.255.0