Connecting SCALANCE M-800 to WAN
1.2 Connecting M81x to ADSL
4. Changing the IP settings of the M81x (Page 34).
5. Configuring the SCALANCE M81x.
– Specifying device information (Page 36)
– Configuring access parameters (Page 37)
– Setting the time (Page 39)
– Allowing access (Page 41).
1.2.2

Setting up SCALANCE M81x and network

Note
Familiarize yourself with the security instructions before you commission the device. You will
find the security instructions in the operating instructions.
Procedure
1. First unpack the M81x and check that it is undamaged.
2. Fit the power supply.
3. Connect the device to the DSL socket on the splitter.
4. Connect the device to the local network via the Ethernet ports.
5. Turn the device on. After connecting up, the fault LED (F) is lit red.
6. Now, turn on the PC.
1.2.3

Launching Web Based Management

In the factory settings, the SCALANCE M-800 can be reached at the following IP address:
● IP address: 192.168.1.1
● Subnet mask: 255.255.255.0
30
WARNING
Use safety extra-low voltage only
The SCALANCE M81x is designed for operation with safety extra-low voltage. This
means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/
VDE0805 can be connected to the power supply terminals.
The power supply unit for the SCALANCE M81x power supply must meet NEC Class 2,
according to the National Electrical Code(r) (ANSI / NFPA 70).
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04