Commissioning; Technical Data; Contact Allocation Table - Festo EduTrainer Manual

Hide thumbs Also See for EduTrainer:
Table of Contents

Advertisement

Available languages

Available languages

5 19-inch module 16DOUT

5.2 Commissioning

1. Connect the inputs/outputs to the PLC using a flat cable:
SV3/SV4: Siemens S7 (16-pin)
SV1/SV2: Other controller types (10-pin)
2. If using modules in parallel, these can be connected via the free insulation-displacement connector
SV1/SV2 or SV3/SV4 using flat cables.
3. Connect the 24 V power supply by means of the 3-pin connector SL1 or SL2.
4. Use the jumper JP1 or JP2 to define whether the output module is supplied directly via 24 V or via
24 V NA. 24 V NA is switched off in the event of an EMERGENCY-STOP
(jumper between pins 1 and 2: supply via 24 V; jumper between pins 2 and 3: supply via 24 V NA).
5. Screw the 19-inch module into the frame.

5.3 Technical data

Operating voltage
Output current
Connection
Front-plate width
Subject to change

5.4 Contact allocation table

Pin
SV1
1
L1+
2
Q0
3
Q1
4
Q2
5
Q3
6
Q4
7
Q5
8
Q6
54
SV2
SV3
SV4
L2+
0V
0V
Q0
Q7
Q7
Q1
0V
0V
Q2
Q6
Q6
Q3
0V
0V
Q4
Q4
Q4
Q5
0V
0V
Q6
Q4
Q4
24 V DC
Max. 0.5 A per output
4 mm safety sockets
12 modules
Pin
SV1
SV2
9
Q7
Q7
10
0V
0V
11
12
13
14
15
16
© Festo Didactic GmbH & Co. KG 739319
SV3
SV4
L1+
L2+
Q3
Q3
L1+
L2+
Q2
Q2
L1+
L2+
Q1
Q1
L1+
L2+
Q0
Q0