6 19-inch module 8DIN

6.2 Commissioning

1. Connect the inputs/outputs to the PLC using a flat cable:
SV2: Siemens S7 (16-pin)
SV1: Other controller types (10-pin)
2. If using modules in parallel, these can be connected via the free insulation-displacement connector SV1
or SV2 using flat cables.
3. Connect the 24 V power supply by means of the 3-pin connector SL1 or SL2.
4. The jumper JP1 defines that the input module is directly supplied via 24 V.
5. Screw the 19-inch module into the frame.

6.3 Technical data

Operating voltage
Input voltage
Connection
Front-plate width
Subject to change

6.4 Contact allocation table

Pin
SV1
1
L1+
I0
2
I1
3
I2
4
I3
5
I4
6
I5
7
I6
8
56
SV2
Pin
0V
9
I7
10
0V
11
I6
12
0V
13
I5
14
0V
15
I4
16
24 V DC
Max. 24 V DC
4 mm safety sockets
6 modules
SV1
SV2
I7
L1+
I3
0V
L1+
I2
L1+
I1
L1+
I0