Commissioning; Technical Data; Contact Allocation Table - Festo EduTrainer Manual

Hide thumbs Also See for EduTrainer:
Table of Contents

Advertisement

Available languages

Available languages

4 19-inch module 16DIN

4.2 Commissioning

1. Connect the inputs/outputs to the PLC using a flat cable:
SV3/SV4: Siemens S7 (16-pin)
SV1/SV2: Other controller types (10-pin)
2. If using modules in parallel, these can be connected via the free insulation-displacement connector
SV1/SV2 or SV3/SV4 using flat cables.
3. Connect the 24 V power supply by means of the 3-pin connector SL1 or SL2.
4. The jumpers JP1 and JP2 define that the input module is directly supplied via 24 V.
5. Screw the 19-inch module into the frame.

4.3 Technical data

Operating voltage
Input voltage
Connection
Front-plate width
Subject to change

4.4 Contact allocation table

Pin
SV1
1
L1+
I0
2
I1
3
I2
4
I3
5
I4
6
I5
7
I6
8
52
SV2
SV3
SV4
L2+
0V
0V
I0
I7
I7
I1
0V
0V
I2
I6
I6
I3
0V
0V
I4
I4
I4
I5
0V
0V
I6
I4
I4
24 V DC
Max. 24 V DC
4 mm safety sockets
12 modules
Pin
SV1
SV2
I7
I7
9
10
0V
0V
11
12
13
14
15
16
© Festo Didactic GmbH & Co. KG 739319
SV3
SV4
L1+
L2+
I3
I3
L1+
L2+
I2
I2
L1+
L2+
I1
I1
L1+
L2+
I0
I0

Advertisement