Overview Of Assemblies; Hmi Color Touch Screen 4,3" And 7 - Eaton CEAG DualGuard-S Mounting And Operating Instructions

Table of Contents

Advertisement

18 Overview of assemblies

18 Overview of assemblies

19 HMI Color Touch Screen 4,3" and 7"

A freely programmable 4.3" / optional 7" dimmable TFT-64k
colour touch display with 480 x 272 pixels 4.3" and 800
x 480 pixels 7" in wide format and 250cd/m² luminance
with touch function over the entire operating surface and
non-volatile program memory with ICON display monitors
and controls the central battery system in conjunction
with the ACU DG module. All functions such as charging,
battery string monitoring, battery block monitoring, bus
phase monitor and insulation monitoring device, mains /
emergency light switching and deep discharge protection
of the devices and the connected emergency lights are
automatically tested. Any faults that occur are reported via
the colour touch screen. An interface enables the connec-
tion of a central visualisation and monitoring device.
Display icons:
Battery voltage, battery strand charging current (+), battery
strand discharge current in test or error case (-), charging
fault, battery block temperature, battery block temperature,
phase monitor function, insulation monitor function, light
fault with destination in plain text, deep discharge protec-
tion, manual reset, emergency light running on (remaining
time in minutes), test mode, date / time, iso fault with des-
tination in plain text, failure UV-AV with destination in plain
text, error information, programming information, test log.
Function icons:
System test, function test, endurance test
3 freely programmable function keys for e.g: Block/enable
system, manual reset, switch on/off continuous light, dis-
play error list, switch on/off passage lighting, simulation
power failure UV
7 control buttons for user-friendly navigation in query and
programming mode.
In addition, each module has a separate service button,
which can be used to show the current module status
directly on the display (immediate analysis).
Programming Icons
Single light monitoring, circuit monitoring, individual name
(20 characters) per device, circuit, light, switch, device
address, selective manual reset, after-running emergency
light (1-15 min.), selective emergency light, LON switch,
timer function, automatic function and operating time test,
selection of menu language, automatic summer time set-
tings, password protection
50
Mounting- and Operating Instruction CEAG DualGuard-S 40071860347 January 2020 www.ceag.de
Internal memory:
Internal memory for archiving the device configuration and
the prescribed test log information for at least 4 years.
Storage of:
• 300,000 test log entries
• Destination texts of the luminaires (40 characters per
luminaire)
• Destination texts of external switches / inputs to phase
monitors, DLS, TLS (40 digits per module)
• names of circuits (40 characters per circuit)
• Name of the installation (40 characters)
Using optional CEAG software, programming can be car-
ried out offline on the PC.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents