Configurations; Description Of Parameters - Record DFA 70 User Manual

Table of Contents

Advertisement

6

Configurations

6.1

Description of parameters

IMPORTANT
With the type "low energy", the parameters can only be changed by qualified personnel.
W = Factory parameter: basic operator (FP)
PARAMETER
DRIVING CYCLE
→ closing speed
→ opening speed
TIME DELAY OPEN
→ time delay open
→ SSK time delay open
NOTICE
The time delay open can be reduced if sensors are used that hold the door open, e.g. hold
time.
DRIVE
→ opening angle
BAL_DFA_70_EN_1V0_REC_102-127109270
W
REMARK
20
Speed when closing the door.
0 = lowest speed
40 = highest speed
– The maximum speed depends on the opening angle and acceleration.
36
Speed when opening the door.
0 = lowest speed
40 = highest speed
– The maximum speed depends on the opening angle and acceleration.
– DIN: >1.5 s <4 s
2
Determines how long the door remains minimally open after it has been
opened by a trigger signal of type AKA, AKI or tap-automatic.
0..20 = 0 to 20 seconds, increment 1 s
21..40 = 22 to 60 seconds, increment 2 s
– The time delay open starts when all trigger and safety signals for
closing stop.
5
Determines the minimum time the door remains open after it has been
opened by a trigger signal of the type SSK.
0..20 = 0 to 20 seconds, increment 1 s
21..40 = 22 to 60 seconds, increment 2 s
– The hold open time starts when all trigger and safety signals for closing
stop.
35
The opening angle is determined during the teach-in run and corresponds
to the value 40.
0 = minimum opening angle
40 = maximum opening angle
– DIN: min. 95°
Configurations
23 / 34
6

Advertisement

Table of Contents
loading

Table of Contents