Operation
Exiting Temperature Setback
Listed below are 3 different ways to exit Temperature Setback.
1. Press and release either Scroll Key (▲ or ▼). This is the preferred
method.
2. Wipe the hot handpiece tip on a wet sponge to lower the tip temperature.
3. Method "1" is preferred but you can turn the Power Switch "OFF" ("0")
and then back "ON" ("I").
Set Tip Temperature and Tip Offset Constant values will be simultaneously restored.
Observe the LED Display as the Operating Tip Temperature stabilizes at the Set Tip
Temperature. For optimum performance, do not attempt to use the attached
handpiece until the Set Tip Temperature is achieved.

Auto Off Safety System

When enabled, the Auto Off safety system of the ST 115 system removes power 10-
90 minutes (enabled/disabled and adjustable in Set-Up Mode) after entering
Temperature Setback.
Operation
When the system has entered Temperature SetBack, an Auto Off timer within the
system circuitry will start running (if Auto Off is turned on in Set-Up Mode):
1. If any key is pressed during the selected time out period, the Auto Off
timer is reset. The system will return to normal operation.
2. At the end of the time out period, the system will enter Auto Off. Power is
removed, the LED Display will show "OFF " and the display will be
flashing.
Exiting Auto Off
Auto Off can be exited; returning to normal operation by:
1. Pressing and releasing a Key (either of the 3 keys).
OR
2. By turning the Power Switch OFF ("0") and then back ON ("I").