Operation
5. Press the Program Key.
normal operation.
6. Observe the Digital Readout as the temperature stabilizes at the desired
Set Tip Temperature
7. Manually force the system into Temperature Setback in the following
manner:
a) Press and hold the Scroll Down (▼) Key and the Scroll Up (▲) Key.
b) Release both keys.
8. The system is now in Temperature Setback. Observe the flashing of the
LED Display and the decreasing of the tip temperature. Allow time for the
temperature to stabilize at 177°C (350°F).
If Auto Off has been enabled (turned on in Set-Up Mode), the system will enter Auto
Off (temperature Off and LED Display flashing "Off") after the preset time of handpiece
inactivity. Auto Off can be exited by pressing any key.
9. Manually force the system out of Temperature Setback in either of the
following manners:
a) Press and release a Key (either of the 3 keys). This is the preferred
method.
b) Wipe the hot handpiece tip on a wet sponge to lower the tip
temperature.
c) Turn the Power Switch Off ("0") and then back on ("I").
10. The system is now in normal operation. Observe the LED Display as the
tip temperature increases to the Set Temperature. Allow time for the
temperature to stabilize at the Set Temperature.
Read the "Operation" and "Set-Up Mode" sections of this manual to utilize the full
capabilities of the system. This is especially important when using large soldering
tips or other SensaTemp handpieces.
11. If you have a Sodr-X-Tractor or other PACE air handpiece connected to
your system, press and hold the handpiece Vacuum Switch. You will hear
a noise as the motor pump starts up and continues to run. Release the
Vacuum Switch.