Pace ST 115 Operation & Maintenance Manual page 33

Table of Contents

Advertisement

Offset Constant
11. The LED Display now shows the stored
Offset Constant with the display alternating
to show "OF" and the stored Offset Constant.
Choose one of the following:
a) Press and release the Program Key to
stored Offset Constant.
b) Press and release the Scroll Up (▲) Key to increase the stored Offset
Constant. An Offset Constant of 0-133°C (0-240°F) can be stored.
Press and release the Program Key to proceed to the next step.
c) Press and release the Scroll Down (▼) Key to decrease the stored
Offset Constant. Press and release the Program Key to proceed to the
next step.
If the attached handpiece is disconnected when the system is powered up, any stored
Offset Constant is reset to zero. The Offset Constant must be entered again in the Set-
Up Mode.
Temperature Setback
12. The LED Display now shows the stored
Temperature Setback time as "S-X" (x=0 thru
9). Time is shown as tens of minutes (e.g., "S-
3" equals 30 minutes). A display of "S- 0"
indicates that Setback is disabled. Choose
one of the following:
a) Press and release the Program Key to
stored Temperature Setback time.
b) Press and release the Scroll Up (▲) Key to enable and/or increase the
stored Temperature Setback time. Press and release the Program Key
to proceed to the next step.
c) Press and release the Scroll Down (▼) Key to decrease or disable the
stored Temperature Setback time. Press and release the Program Key
to proceed to the next step.
keep the currently
NOTE
keep the currently
Set-Up Mode
29